Ankerui Electric ADW210-D10-1S data acquisition

- +
Custom Settings Company Homepage More Products

The quotes are provided by Several Partner Companies

  • Prices: Request for a Quote for Further Details
  • Model : ADW210-D10-1S
  • Category: Data Collecting Instrument
  • Brand : Ankerui Electric
  • Delivery Time: Request for a Quote for Further Details
  • Manufacturer: Ankerui Electric

Products

describe:

ADW200 series rail-type multi-circuit power meters are mainly used for measuring all electrical parameters of three-phase circuits,and can select the current input of four circuits at the same time. It can directly or indirectly measure voltage,current,power,power factor,phase,unbalance,harmonics and other parameters. The instrument can have RS485 communication,active pulse output,or two switching inputs/two switching outputs; or 12 external NTC temperature measurements + 4 residual current measurements; or 12 switching inputs + 4 Switching output. Can have button operation and LCD display or LoRa wireless communication. According to different requirements,parameters such as communication and alarm can be set and controlled through the buttons on the instrument panel.


Function:

The ADW2xx series of rail-mounted multi-circuit power meters are mainly used for measuring all electrical parameters of low-voltage three-phase circuits. At the same time,the current input of four circuits can be selected. It can directly or indirectly measure voltage,current,power,power factor,phase,unbalance,harmonics and other parameters. It can also expand auxiliary functions through its RJ45 interface to realize DI,DO,temperature measurement,residual current measurement,and 2G,4G,LoRa,LoRaWan,and NB-Lot wireless communication functions.


Application scope:

The ADW2xx series of rail-type multi-circuit power meters facilitate users to monitor,collect and manage power consumption. It can be flexibly installed in the distribution box to realize sub-item electric energy measurement,statistics and analysis in different areas and different loads.


Ordering example:

Specific model: ADW200-D10-4S-MK
Technical requirements: 100A
Communication protocol: RS485 interface,Modbus-RTU protocol
Auxiliary power supply: AC/DC 85~265V

The main function


N (1,2,3,4) three-phase circuit full electrical parameter measurement;

The transformer is external;

Three-phase voltage and current,zero sequence current,frequency;

Three-phase power,total power (active,reactive,apparent);

Three-phase power factor,total power factor;

Voltage and current phase,voltage and current imbalance;

Voltage and current total harmonics and 2-31 sub-harmonics;

Voltage,current,and power extreme value records for the current month and the previous month;

Maximum current and power demand and real-time current and power demand;

200 event records,recording DIDO’s actions;

Supports overvoltage,overcurrent,phase failure,D1 linkage and other alarm outputs;

Rate settings for 4 time zones and 14 time periods;

Four-quadrant electric energy,12-month compound rate electric energy statistics;

31-day four-quadrant and multi-rate electric energy freeze;

The accuracy of active electric energy is Level 1,and the accuracy of reactive energy is Level 2.

Standard functions: 2D12D0; 1 channel RS485; 1 channel active pulse output (corresponding circuit can be switched).

Extended functions: Extend auxiliary functions through RJ45 interface.

ADW200: None

ADW210: Additional key operation and LCD display

ADW220: additionally equipped with LoRa wireless communication