Hebei OSU Electronics Building Multi-parameter Sensor Gas Instrument

- +
Custom Settings Company Homepage More Products

The quotes are provided by Several Partner Companies

  • Prices: Request for a Quote for Further Details
  • Model : Building multi-parameter sensors
  • Category: Gas Equipment
  • Brand : Hebei North Speed ​​Electronics
  • Delivery Time: Request for a Quote for Further Details
  • Manufacturer: Hebei North Speed ​​Electronics

Products



1

Overview

multi-parameter sensorIt is a product independently developed by our company.All adopt imported data acquisition chips and advanced production technology and surface mount technology,so the measurement data is accurate and reliable. It has been carefully calibrated during production,and the calibration data is stored in the internal memory. It is outst in terms of measurement accuracy,linearity,repeatability,interconvertibility,and consistency. In addition,the sensor has digital output and is fully interconvertible. It does not require complex verification and calibration. It is suitable for environmental equipment matching,instrument equipment integration,and a large number of general environmental tests.

Multi-parameter sensors can output a variety of signals,and wired output signals includeRS485signals and voltage and current signals; wireless output includesLoRa,Bluetooth,WIFIGPRS4GNB-lOT,wireless output exceptLoRa,Bluetooth,the other four forms can be connected to the Osu Smart Cloud Platform to realize the monitoring and management of smart terminal data.RJ45There are three protocols for network output (1,cloud platform protocol,upload directly to the server;2,standardModbus-RTUprotocol;3,standardModbus-TCPprotocol).In addition,the sensor has built-in12relay switch output,buzzer prompts alarm. accessibleRS485Freely set the high limit or low limit alarm value of any parameter.

The parameters that multi-parameter sensors can monitor include air temperature,air humidity,CO2concentration,COconcentration,PM1.0/2.5/10.0,atmospheric pressure,formaldehyde,oxygen,ozone,volatile organic compounds,air quality,etc. (the measured parameters are customized according to needs),the monitoring parameters are complete,and the measurement data is accurate.


2

Features

1Multiple parameters can be detected simultaneously,and users canaccording toAny customized parameter type required

2Rich human-machine interface,color screen interface designed based on the latest embedded ideas,can display real-time data of single or multiple parameters

3High integration,low power consumption and life

4Really realize low cost,low price and high performance

5Building-style housing is compact and easy to install.

6Screen background color can be customized and font color can be changed

7built-in12relay switch output,buzzer prompts alarm

8Digital linearization correction,high precision and stability


3

Scope of application

This product can be widely used in chemical fertilizers,biomedicine,food safety,environmental protection supervision,agricultural greenhouses,industrial production,livestock breeding,construction buildings,meteorological environmental protection,gardening flowers,home life and other fields that need to monitor environmental meteorology.


4

Product information

4.1Technical Parameters

Technical Parameters

Measuring range

resolution

Accuracy

temperature

3070

0.1

±0. 2

humidity

0100%RH

0.1%RH

±3%RH

Illumination

0200K Lux

10 Lux

±5%

dew point temperature

10040

0.1

±0. 3

air pressure

6001100hPa

0.1hPa

±0.5hPa

CO2

05000ppm

1ppm

±75ppm2%reading

CivilianCO

0500ppm

0.1ppm

±2%FS

PM1.0/2.5/10

01000μg/m3

1μg/m3

±3%FS

TVOC

05000ppb

1ppb

±3%

CH2O

05000ppb

10ppb

±3%

O2

025%VOL

0.1%VOL

±2%FS

O3

010ppm

0.01ppm

±2%FS

air quality

010mg/m3

0.05 mg/m3

±2%FS

NH3

0100ppm

1ppm

±2%FS

H2S

0100ppm

1ppm

±2%FS

NO2

020ppm

0.1ppm

±2%FS

stink

050ppm

0.01ppm

±2%FS

SO2

020ppm

0.1ppm

±2%FS

Cl2

010ppm

0.1ppm

±2%FS

domestic gas

05000ppm

50ppm

±3%LEL

output signal:ARS485(standardModbus-RTUProtocol,device default address:01

B: Reserve two analog signals:

Voltage signal:02V05V010V,choose one of the three

Current signal:420 mA(current loop)

CSwitch output,relay control,buzzer prompt alarm

Contact rating:5AAC250V5ADC30V

D:wireless signal:LoRa,Bluetooth,WIFIGPRS4GNB-lOT

E:Ethernet:RJ45Network port

Power supply:1DC1224Vpowered by2:standardPOEpowered by(48V

Protocol:1:Cloud platform protocol

2:standardModbus-RTUprotocol

3:standardModbus-TCPprotocol

Supply voltage:1224V DC

Stable time:<1Second

Response time:<1Second

Workenvironment:temperature3085humidity:095%RH

Heavycomplexsex:2%FS

stableCertainlysex:1%FS

Cable specifications:2rice4Wire system (RS4852rice3Wire system (analog signal)(Cable length optional)

4.2Impedance Requirements for Current Signals

Supply voltage

9V

12V

20V

24V

maximum impedance

125Ω

250Ω

500Ω

>500Ω


5

product specifications


6

Instructions

The multi-parameter sensor wiring instructions are as follows:


7

Data conversion method

V: The voltage value collected by the collector,unit:V

A: Current value collected by the collector,unit:mA

output signal

Data conversion methods for each parameter

02V DC

MeasurementsV÷2×Measuring range

05V DC

Measured value =V÷5×Measuring range

010V DC

Measured value =V÷10×Measuring range

420mA

Measurement value = (A4÷16×Measuring range

RS485signal (default address01):

standardModbus-RTUProtocol,baud rate:9600;Check bit: none;Data bit:8;Stop bit:1

7.1address

For example: the address to1The sensor address is changed to2,hostSlave machine

original address

function code

Start register high

Start register low

Starting address high

Starting address is low

CRC16Low

CRC16high

0X01

0X06

0X00

0X30

0X00

0X02

0X08

0X04

If the sensor receives correctly,the data will be returned along the original path.

Note: If you forget the original address of the sensor,you can use the broadcast address0XFEInstead,use0XFEAt this time,the host can only connect one slave,and the return address is still the original address,which can be used as an address query method.

7.2Query data

Query the sensor (address is1)The data21parameters),hostSlave machine

address

function code

Starting register address high

Starting register address low

Register length is high

Register length is low

CRC16Low

CRC16high

0X01

0X03

0X00

0X00

0X00

0X15

0X84

0X05

If the sensor receives correctly,the following data will be returned,and the slaveHost

address

0X01


function code

0X03


Data length

0X2A


register0High data

0X00

temperature:23.4℃

Negative numbers are expressed using two’s complement code

register0data low

0XEA

register1High data

0X00

humidity:22.2%RH

register1data low

0XDE

register2High data

0X27

Air pressure:1000.0hPa

register2data low

0X10

register3High data

0X03

CO2concentration:888ppm

register3data low

0X78

register4High data

0X00

COconcentration:22.2ppm

register4data low

0XDE

register5High data

0X00

PM1.022μg/m3

register5data low

0X16

register6High data

0X00

PM2.5122μg/m3

register6data low

0X7A

register7High data

0X00

PM10134μg/m3

register7data low

0X86

register8High data

0X00

formaldehyde:2220ppb

register8data low

0XDE

register9High data

0X00

oxygen:22.2%VOL

register9data low

0XDE

register10High data

0X01

ozone:3.33ppm

register10data low

0X4D

register11High data

0X00

TVOC99ppb

register11data low

0X63

register12High data

0X02

air quality:5.55mg/m3

register12data low

0X2B

register13High data

0X00

H2S22ppm

register13data low

0X16

register14High data

0X00

NH322ppm

register14data low

0X16

register15High data

0X00

NO28.8ppm

register15data low

0X58

register16High data

0X03

Odor:8.88ppm

register16data low

0X78

register17High data

0X00

Dew point temperature:10.5℃

register17data low

0X69

register18High data

0X00

Chlorine:2.2ppm

register18data low

0X16

register19High data

0X00

SO22.2ppm

register19data low

0X16

register20High data

0X00

Civil gas:100ppm

register20data low

0X64

CRC16Low

0X4B


CRC16high

0X8C



8

Precautions for use

1Please check whether the packaging is intact and whether the transmitter model and specifications match the product you purchased.

2Do not connect while the power is on. Only after the wiring is completed and checked are correct can the power be turned on.

3Users should not modify the soldered components and connected wires of this product when it leaves the factory.

4The sensor is a precision device. Users should not disassemble it by themselves when using it,let alone touch the diaphragm to avoid damage to the product.

5Avoid sticky particles from entering the sensor and prevent moisture from affecting the measurement performance.


9

Product warranty

The warranty period of this product is one year. Within twelve months from the date of shipment,our company will be responsible for free repair or replacement of any failure caused by sensor quality problems (non-human damage). After the warranty period,only the cost will be charged.



1

Overview

multi-parameter sensorIt is a product independently developed by our company.All adopt imported data acquisition chips and advanced production technology and surface mount technology,so the measurement data is accurate and reliable. It has been carefully calibrated during production,and the calibration data is stored in the internal memory. It is outst in terms of measurement accuracy,linearity,repeatability,interconvertibility,and consistency. In addition,the sensor has digital output and is fully interconvertible. It does not require complex verification and calibration. It is suitable for environmental equipment matching,instrument equipment integration,and a large number of general environmental tests.

Multi-parameter sensors can output a variety of signals,and wired output signals includeRS485signals and voltage and current signals; wireless output includesLoRa,Bluetooth,WIFIGPRS4GNB-lOT,wireless output exceptLoRa,Bluetooth,the other four forms can be connected to the Osu Smart Cloud Platform to realize the monitoring and management of smart terminal data.RJ45There are three protocols for network output (1,cloud platform protocol,upload directly to the server;2,standardModbus-RTUprotocol;3,standardModbus-TCPprotocol).In addition,the sensor has built-in12relay switch output,buzzer prompts alarm. accessibleRS485Freely set the high limit or low limit alarm value of any parameter.

The parameters that multi-parameter sensors can monitor include air temperature,air humidity,CO2concentration,COconcentration,PM1.0/2.5/10.0,atmospheric pressure,formaldehyde,oxygen,ozone,volatile organic compounds,air quality,etc. (the measured parameters are customized according to needs),the monitoring parameters are complete,and the measurement data is accurate.


2

Features

1Multiple parameters can be detected simultaneously,and users canaccording toAny customized parameter type required

2Rich human-machine interface,color screen interface designed based on the latest embedded ideas,can display real-time data of single or multiple parameters

3High integration,low power consumption and life

4Really realize low cost,low price and high performance

5Building-style housing is compact and easy to install.

6Screen background color can be customized and font color can be changed

7built-in12relay switch output,buzzer prompts alarm

8Digital linearization correction,high precision and stability


3

Scope of application

This product can be widely used in chemical fertilizers,biomedicine,food safety,environmental protection supervision,agricultural greenhouses,industrial production,livestock breeding,construction buildings,meteorological environmental protection,gardening flowers,home life and other fields that need to monitor environmental meteorology.


4

Product information

4.1Technical Parameters

Technical Parameters

Measuring range

resolution

Accuracy

temperature

3070

0.1

±0. 2

humidity

0100%RH

0.1%RH

±3%RH

Illumination

0200K Lux

10 Lux

±5%

dew point temperature

10040

0.1

±0. 3

air pressure

6001100hPa

0.1hPa

±0.5hPa

CO2

05000ppm

1ppm

±75ppm2%reading

CivilianCO

0500ppm

0.1ppm

±2%FS

PM1.0/2.5/10

01000μg/m3

1μg/m3

±3%FS

TVOC

05000ppb

1ppb

±3%

CH2O

05000ppb

10ppb

±3%

O2

025%VOL

0.1%VOL

±2%FS

O3

010ppm

0.01ppm

±2%FS

air quality

010mg/m3

0.05 mg/m3

±2%FS

NH3

0100ppm

1ppm

±2%FS

H2S

0100ppm

1ppm

±2%FS

NO2

020ppm

0.1ppm

±2%FS

stink

050ppm

0.01ppm

±2%FS

SO2

020ppm

0.1ppm

±2%FS

Cl2

010ppm

0.1ppm

±2%FS

domestic gas

05000ppm

50ppm

±3%LEL

output signal:ARS485(standardModbus-RTUProtocol,device default address:01

B: Reserve two analog signals:

Voltage signal:02V05V010V,choose one of the three

Current signal:420 mA(current loop)

CSwitch output,relay control,buzzer prompt alarm

Contact rating:5AAC250V5ADC30V

D:wireless signal:LoRa,Bluetooth,WIFIGPRS4GNB-lOT

E:Ethernet:RJ45Network port

Power supply:1DC1224Vpowered by2:standardPOEpowered by(48V

Protocol:1:Cloud platform protocol

2:standardModbus-RTUprotocol

3:standardModbus-TCPprotocol

Supply voltage:1224V DC

Stable time:<1Second

Response time:<1Second

Workenvironment:temperature3085humidity:095%RH

Heavycomplexsex:2%FS

stableCertainlysex:1%FS

Cable specifications:2rice4Wire system (RS4852rice3Wire system (analog signal)(Cable length optional)

4.2Impedance Requirements for Current Signals

Supply voltage

9V

12V

20V

24V

maximum impedance

125Ω

250Ω

500Ω

>500Ω


5

product specifications


6

Instructions

The multi-parameter sensor wiring instructions are as follows:


7

Data conversion method

V: The voltage value collected by the collector,unit:V

A: Current value collected by the collector,unit:mA

output signal

Data conversion methods for each parameter

02V DC

MeasurementsV÷2×Measuring range

05V DC

Measured value =V÷5×Measuring range

010V DC

Measured value =V÷10×Measuring range

420mA

Measurement value = (A4÷16×Measuring range

RS485signal (default address01):

standardModbus-RTUProtocol,baud rate:9600;Check bit: none;Data bit:8;Stop bit:1

7.1address

For example: the address to1The sensor address is changed to2,hostSlave machine

original address

function code

Start register high

Start register low

Starting address high

Starting address is low

CRC16Low

CRC16high

0X01

0X06

0X00

0X30

0X00

0X02

0X08

0X04

If the sensor receives correctly,the data will be returned along the original path.

Note: If you forget the original address of the sensor,you can use the broadcast address0XFEInstead,use0XFEAt this time,the host can only connect one slave,and the return address is still the original address,which can be used as an address query method.

7.2Query data

Query the sensor (address is1)The data21parameters),hostSlave machine

address

function code

Starting register address high

Starting register address low

Register length is high

Register length is low

CRC16Low

CRC16high

0X01

0X03

0X00

0X00

0X00

0X15

0X84

0X05

If the sensor receives correctly,the following data will be returned,and the slaveHost

address

0X01


function code

0X03


Data length

0X2A


register0High data

0X00

temperature:23.4℃

Negative numbers are expressed using two’s complement code

register0data low

0XEA

register1High data

0X00

humidity:22.2%RH

register1data low

0XDE

register2High data

0X27

Air pressure:1000.0hPa

register2data low

0X10

register3High data

0X03

CO2concentration:888ppm

register3data low

0X78

register4High data

0X00

COconcentration:22.2ppm

register4data low

0XDE

register5High data

0X00

PM1.022μg/m3

register5data low

0X16

register6High data

0X00

PM2.5122μg/m3

register6data low

0X7A

register7High data

0X00

PM10134μg/m3

register7data low

0X86

register8High data

0X00

formaldehyde:2220ppb

register8data low

0XDE

register9High data

0X00

oxygen:22.2%VOL

register9data low

0XDE

register10High data

0X01

ozone:3.33ppm

register10data low

0X4D

register11High data

0X00

TVOC99ppb

register11data low

0X63

register12High data

0X02

air quality:5.55mg/m3

register12data low

0X2B

register13High data

0X00

H2S22ppm

register13data low

0X16

register14High data

0X00

NH322ppm

register14data low

0X16

register15High data

0X00

NO28.8ppm

register15data low

0X58

register16High data

0X03

Odor:8.88ppm

register16data low

0X78

register17High data

0X00

Dew point temperature:10.5℃

register17data low

0X69

register18High data

0X00

Chlorine:2.2ppm

register18data low

0X16

register19High data

0X00

SO22.2ppm

register19data low

0X16

register20High data

0X00

Civil gas:100ppm

register20data low

0X64

CRC16Low

0X4B


CRC16high

0X8C



8

Precautions for use

1Please check whether the packaging is intact and whether the transmitter model and specifications match the product you purchased.

2Do not connect while the power is on. Only after the wiring is completed and checked are correct can the power be turned on.

3Users should not modify the soldered components and connected wires of this product when it leaves the factory.

4The sensor is a precision device. Users should not disassemble it by themselves when using it,let alone touch the diaphragm to avoid damage to the product.

5Avoid sticky particles from entering the sensor and prevent moisture from affecting the measurement performance.


9

Product warranty

The warranty period of this product is one year. Within twelve months from the date of shipment,our company will be responsible for free repair or replacement of any failure caused by sensor quality problems (non-human damage). After the warranty period,only the cost will be charged.