Hebei OSU Electronics Building Multi-parameter Sensor Gas Instrument
- Prices: Request for a Quote for Further Details
- Model : Building multi-parameter sensors
- Category: Gas Equipment
- Brand : Hebei North Speed Electronics
- Delivery Time: Request for a Quote for Further Details
- Manufacturer: Hebei North Speed Electronics
Products
| Overview |
multi-parameter sensorIt is a product independently developed by our company.All adopt imported data acquisition chips and advanced production technology and surface mount technology,so the measurement data is accurate and reliable. It has been carefully calibrated during production,and the calibration data is stored in the internal memory. It is outst in terms of measurement accuracy,linearity,repeatability,interconvertibility,and consistency. In addition,the sensor has digital output and is fully interconvertible. It does not require complex verification and calibration. It is suitable for environmental equipment matching,instrument equipment integration,and a large number of general environmental tests.
Multi-parameter sensors can output a variety of signals,and wired output signals includeRS485signals and voltage and current signals; wireless output includesLoRa,Bluetooth,WIFI、GPRS、4G、NB-lOT,wireless output exceptLoRa,Bluetooth,the other four forms can be connected to the Osu Smart Cloud Platform to realize the monitoring and management of smart terminal data.;RJ45There are three protocols for network output (1,cloud platform protocol,upload directly to the server;2,standardModbus-RTUprotocol;3,standardModbus-TCPprotocol).In addition,the sensor has built-in1~2relay switch output,buzzer prompts alarm. accessibleRS485Freely set the high limit or low limit alarm value of any parameter.
The parameters that multi-parameter sensors can monitor include air temperature,air humidity,CO2concentration,COconcentration,PM1.0/2.5/10.0,atmospheric pressure,formaldehyde,oxygen,ozone,volatile organic compounds,air quality,etc. (the measured parameters are customized according to needs),the monitoring parameters are complete,and the measurement data is accurate.
| Features |
(1)Multiple parameters can be detected simultaneously,and users canaccording toAny customized parameter type required。
(2)Rich human-machine interface,color screen interface designed based on the latest embedded ideas,can display real-time data of single or multiple parameters。
(3)High integration,low power consumption and life。
(4)Really realize low cost,low price and high performance。
(5)Building-style housing is compact and easy to install.。
(6)Screen background color can be customized and font color can be changed。
(7)built-in1~2relay switch output,buzzer prompts alarm。
(8)Digital linearization correction,high precision and stability。
| Scope of application |
This product can be widely used in chemical fertilizers,biomedicine,food safety,environmental protection supervision,agricultural greenhouses,industrial production,livestock breeding,construction buildings,meteorological environmental protection,gardening flowers,home life and other fields that need to monitor environmental meteorology.
| Product information |
4.1Technical Parameters
Technical Parameters | Measuring range | resolution | Accuracy |
temperature | -30℃~70℃ | 0.1℃ | ±0. 2℃ |
humidity | 0~100%RH | 0.1%RH | ±3%RH |
Illumination | 0~200K Lux | 10 Lux | ±5% |
dew point temperature | -100℃~40℃ | 0.1℃ | ±0. 3℃ |
air pressure | 600~1100hPa | 0.1hPa | ±0.5hPa |
CO2 | 0~5000ppm | 1ppm | ±75ppm+2%reading |
CivilianCO | 0~500ppm | 0.1ppm | ±2%FS |
PM1.0/2.5/10 | 0~1000μg/m3 | 1μg/m3 | ±3%FS |
TVOC | 0~5000ppb | 1ppb | ±3% |
CH2O | 0~5000ppb | 10ppb | ±3% |
O2 | 0~25%VOL | 0.1%VOL | ±2%FS |
O3 | 0~10ppm | 0.01ppm | ±2%FS |
air quality | 0~10mg/m3 | 0.05 mg/m3 | ±2%FS |
NH3 | 0~100ppm | 1ppm | ±2%FS |
H2S | 0~100ppm | 1ppm | ±2%FS |
NO2 | 0~20ppm | 0.1ppm | ±2%FS |
stink | 0~50ppm | 0.01ppm | ±2%FS |
SO2 | 0~20ppm | 0.1ppm | ±2%FS |
Cl2 | 0~10ppm | 0.1ppm | ±2%FS |
domestic gas | 0~5000ppm | 50ppm | ±3%LEL |
output signal:A:RS485(standardModbus-RTUProtocol,device default address:01)
B: Reserve two analog signals:
Voltage signal:0~2V,0~5V,0~10V,choose one of the three
Current signal:4~20 mA(current loop)
C:Switch output,relay control,buzzer prompt alarm
Contact rating:5AAC250V;5ADC30V
D:wireless signal:LoRa,Bluetooth,WIFI、GPRS、4G、NB-lOT
E:Ethernet:RJ45Network port
Power supply:1:DC12~24Vpowered by;2:standardPOEpowered by(48V)
Protocol:1:Cloud platform protocol
2:standardModbus-RTUprotocol
3:standardModbus-TCPprotocol
Supply voltage:12~24V DC
Stable time:<1Second
Response time:<1Second
Workenvironment:temperature:-30℃~85℃;humidity:0~95%RH
Heavycomplexsex:≤2%FS
stableCertainlysex:≤1%FS
Cable specifications:2rice4Wire system (RS485);2rice3Wire system (analog signal)(Cable length optional)
4.2Impedance Requirements for Current Signals
Supply voltage | 9V | 12V | 20V | 24V |
maximum impedance | 125Ω | 250Ω | 500Ω | >500Ω |
| product specifications |
| Instructions |
The multi-parameter sensor wiring instructions are as follows:
| Data conversion method |
V: The voltage value collected by the collector,unit:V;
A: Current value collected by the collector,unit:mA;
output signal | Data conversion methods for each parameter |
0~2V DC | Measurements=V÷2×Measuring range |
0~5V DC | Measured value =V÷5×Measuring range |
0~10V DC | Measured value =V÷10×Measuring range |
4~20mA | Measurement value = (A-4)÷16×Measuring range |
RS485signal (default address01):
standardModbus-RTUProtocol,baud rate:9600;Check bit: none;Data bit:8;Stop bit:1
7.1address
For example: the address to1The sensor address is changed to2,host→Slave machine
original address | function code | Start register high | Start register low | Starting address high | Starting address is low | CRC16Low | CRC16high |
0X01 | 0X06 | 0X00 | 0X30 | 0X00 | 0X02 | 0X08 | 0X04 |
If the sensor receives correctly,the data will be returned along the original path.。
Note: If you forget the original address of the sensor,you can use the broadcast address0XFEInstead,use0XFEAt this time,the host can only connect one slave,and the return address is still the original address,which can be used as an address query method.
7.2Query data
Query the sensor (address is1)The data(21parameters),host→Slave machine
address | function code | Starting register address high | Starting register address low | Register length is high | Register length is low | CRC16Low | CRC16high |
0X01 | 0X03 | 0X00 | 0X00 | 0X00 | 0X15 | 0X84 | 0X05 |
If the sensor receives correctly,the following data will be returned,and the slave→Host
address | 0X01 | |
function code | 0X03 | |
Data length | 0X2A | |
register0High data | 0X00 | temperature:23.4℃ Negative numbers are expressed using two’s complement code |
register0data low | 0XEA | |
register1High data | 0X00 | humidity:22.2%RH |
register1data low | 0XDE | |
register2High data | 0X27 | Air pressure:1000.0hPa |
register2data low | 0X10 | |
register3High data | 0X03 | CO2concentration:888ppm |
register3data low | 0X78 | |
register4High data | 0X00 | COconcentration:22.2ppm |
register4data low | 0XDE | |
register5High data | 0X00 | PM1.0:22μg/m3 |
register5data low | 0X16 | |
register6High data | 0X00 | PM2.5:122μg/m3 |
register6data low | 0X7A | |
register7High data | 0X00 | PM10:134μg/m3 |
register7data low | 0X86 | |
register8High data | 0X00 | formaldehyde:2220ppb |
register8data low | 0XDE | |
register9High data | 0X00 | oxygen:22.2%VOL |
register9data low | 0XDE | |
register10High data | 0X01 | ozone:3.33ppm |
register10data low | 0X4D | |
register11High data | 0X00 | TVOC:99ppb |
register11data low | 0X63 | |
register12High data | 0X02 | air quality:5.55mg/m3 |
register12data low | 0X2B | |
register13High data | 0X00 | H2S:22ppm |
register13data low | 0X16 | |
register14High data | 0X00 | NH3:22ppm |
register14data low | 0X16 | |
register15High data | 0X00 | NO2:8.8ppm |
register15data low | 0X58 | |
register16High data | 0X03 | Odor:8.88ppm |
register16data low | 0X78 | |
register17High data | 0X00 | Dew point temperature:10.5℃ |
register17data low | 0X69 | |
register18High data | 0X00 | Chlorine:2.2ppm |
register18data low | 0X16 | |
register19High data | 0X00 | SO2:2.2ppm |
register19data low | 0X16 | |
register20High data | 0X00 | Civil gas:100ppm |
register20data low | 0X64 | |
CRC16Low | 0X4B | |
CRC16high | 0X8C |
| Precautions for use |
(1)Please check whether the packaging is intact and whether the transmitter model and specifications match the product you purchased.。
(2)Do not connect while the power is on. Only after the wiring is completed and checked are correct can the power be turned on.。
(3)Users should not modify the soldered components and connected wires of this product when it leaves the factory.。
(4)The sensor is a precision device. Users should not disassemble it by themselves when using it,let alone touch the diaphragm to avoid damage to the product.。
(5)Avoid sticky particles from entering the sensor and prevent moisture from affecting the measurement performance.
| Product warranty |
The warranty period of this product is one year. Within twelve months from the date of shipment,our company will be responsible for free repair or replacement of any failure caused by sensor quality problems (non-human damage). After the warranty period,only the cost will be charged.
| Overview |
multi-parameter sensorIt is a product independently developed by our company.All adopt imported data acquisition chips and advanced production technology and surface mount technology,so the measurement data is accurate and reliable. It has been carefully calibrated during production,and the calibration data is stored in the internal memory. It is outst in terms of measurement accuracy,linearity,repeatability,interconvertibility,and consistency. In addition,the sensor has digital output and is fully interconvertible. It does not require complex verification and calibration. It is suitable for environmental equipment matching,instrument equipment integration,and a large number of general environmental tests.
Multi-parameter sensors can output a variety of signals,and wired output signals includeRS485signals and voltage and current signals; wireless output includesLoRa,Bluetooth,WIFI、GPRS、4G、NB-lOT,wireless output exceptLoRa,Bluetooth,the other four forms can be connected to the Osu Smart Cloud Platform to realize the monitoring and management of smart terminal data.;RJ45There are three protocols for network output (1,cloud platform protocol,upload directly to the server;2,standardModbus-RTUprotocol;3,standardModbus-TCPprotocol).In addition,the sensor has built-in1~2relay switch output,buzzer prompts alarm. accessibleRS485Freely set the high limit or low limit alarm value of any parameter.
The parameters that multi-parameter sensors can monitor include air temperature,air humidity,CO2concentration,COconcentration,PM1.0/2.5/10.0,atmospheric pressure,formaldehyde,oxygen,ozone,volatile organic compounds,air quality,etc. (the measured parameters are customized according to needs),the monitoring parameters are complete,and the measurement data is accurate.
| Features |
(1)Multiple parameters can be detected simultaneously,and users canaccording toAny customized parameter type required。
(2)Rich human-machine interface,color screen interface designed based on the latest embedded ideas,can display real-time data of single or multiple parameters。
(3)High integration,low power consumption and life。
(4)Really realize low cost,low price and high performance。
(5)Building-style housing is compact and easy to install.。
(6)Screen background color can be customized and font color can be changed。
(7)built-in1~2relay switch output,buzzer prompts alarm。
(8)Digital linearization correction,high precision and stability。
| Scope of application |
This product can be widely used in chemical fertilizers,biomedicine,food safety,environmental protection supervision,agricultural greenhouses,industrial production,livestock breeding,construction buildings,meteorological environmental protection,gardening flowers,home life and other fields that need to monitor environmental meteorology.
| Product information |
4.1Technical Parameters
Technical Parameters | Measuring range | resolution | Accuracy |
temperature | -30℃~70℃ | 0.1℃ | ±0. 2℃ |
humidity | 0~100%RH | 0.1%RH | ±3%RH |
Illumination | 0~200K Lux | 10 Lux | ±5% |
dew point temperature | -100℃~40℃ | 0.1℃ | ±0. 3℃ |
air pressure | 600~1100hPa | 0.1hPa | ±0.5hPa |
CO2 | 0~5000ppm | 1ppm | ±75ppm+2%reading |
CivilianCO | 0~500ppm | 0.1ppm | ±2%FS |
PM1.0/2.5/10 | 0~1000μg/m3 | 1μg/m3 | ±3%FS |
TVOC | 0~5000ppb | 1ppb | ±3% |
CH2O | 0~5000ppb | 10ppb | ±3% |
O2 | 0~25%VOL | 0.1%VOL | ±2%FS |
O3 | 0~10ppm | 0.01ppm | ±2%FS |
air quality | 0~10mg/m3 | 0.05 mg/m3 | ±2%FS |
NH3 | 0~100ppm | 1ppm | ±2%FS |
H2S | 0~100ppm | 1ppm | ±2%FS |
NO2 | 0~20ppm | 0.1ppm | ±2%FS |
stink | 0~50ppm | 0.01ppm | ±2%FS |
SO2 | 0~20ppm | 0.1ppm | ±2%FS |
Cl2 | 0~10ppm | 0.1ppm | ±2%FS |
domestic gas | 0~5000ppm | 50ppm | ±3%LEL |
output signal:A:RS485(standardModbus-RTUProtocol,device default address:01)
B: Reserve two analog signals:
Voltage signal:0~2V,0~5V,0~10V,choose one of the three
Current signal:4~20 mA(current loop)
C:Switch output,relay control,buzzer prompt alarm
Contact rating:5AAC250V;5ADC30V
D:wireless signal:LoRa,Bluetooth,WIFI、GPRS、4G、NB-lOT
E:Ethernet:RJ45Network port
Power supply:1:DC12~24Vpowered by;2:standardPOEpowered by(48V)
Protocol:1:Cloud platform protocol
2:standardModbus-RTUprotocol
3:standardModbus-TCPprotocol
Supply voltage:12~24V DC
Stable time:<1Second
Response time:<1Second
Workenvironment:temperature:-30℃~85℃;humidity:0~95%RH
Heavycomplexsex:≤2%FS
stableCertainlysex:≤1%FS
Cable specifications:2rice4Wire system (RS485);2rice3Wire system (analog signal)(Cable length optional)
4.2Impedance Requirements for Current Signals
Supply voltage | 9V | 12V | 20V | 24V |
maximum impedance | 125Ω | 250Ω | 500Ω | >500Ω |
| product specifications |
| Instructions |
The multi-parameter sensor wiring instructions are as follows:
| Data conversion method |
V: The voltage value collected by the collector,unit:V;
A: Current value collected by the collector,unit:mA;
output signal | Data conversion methods for each parameter |
0~2V DC | Measurements=V÷2×Measuring range |
0~5V DC | Measured value =V÷5×Measuring range |
0~10V DC | Measured value =V÷10×Measuring range |
4~20mA | Measurement value = (A-4)÷16×Measuring range |
RS485signal (default address01):
standardModbus-RTUProtocol,baud rate:9600;Check bit: none;Data bit:8;Stop bit:1
7.1address
For example: the address to1The sensor address is changed to2,host→Slave machine
original address | function code | Start register high | Start register low | Starting address high | Starting address is low | CRC16Low | CRC16high |
0X01 | 0X06 | 0X00 | 0X30 | 0X00 | 0X02 | 0X08 | 0X04 |
If the sensor receives correctly,the data will be returned along the original path.。
Note: If you forget the original address of the sensor,you can use the broadcast address0XFEInstead,use0XFEAt this time,the host can only connect one slave,and the return address is still the original address,which can be used as an address query method.
7.2Query data
Query the sensor (address is1)The data(21parameters),host→Slave machine
address | function code | Starting register address high | Starting register address low | Register length is high | Register length is low | CRC16Low | CRC16high |
0X01 | 0X03 | 0X00 | 0X00 | 0X00 | 0X15 | 0X84 | 0X05 |
If the sensor receives correctly,the following data will be returned,and the slave→Host
address | 0X01 | |
function code | 0X03 | |
Data length | 0X2A | |
register0High data | 0X00 | temperature:23.4℃ Negative numbers are expressed using two’s complement code |
register0data low | 0XEA | |
register1High data | 0X00 | humidity:22.2%RH |
register1data low | 0XDE | |
register2High data | 0X27 | Air pressure:1000.0hPa |
register2data low | 0X10 | |
register3High data | 0X03 | CO2concentration:888ppm |
register3data low | 0X78 | |
register4High data | 0X00 | COconcentration:22.2ppm |
register4data low | 0XDE | |
register5High data | 0X00 | PM1.0:22μg/m3 |
register5data low | 0X16 | |
register6High data | 0X00 | PM2.5:122μg/m3 |
register6data low | 0X7A | |
register7High data | 0X00 | PM10:134μg/m3 |
register7data low | 0X86 | |
register8High data | 0X00 | formaldehyde:2220ppb |
register8data low | 0XDE | |
register9High data | 0X00 | oxygen:22.2%VOL |
register9data low | 0XDE | |
register10High data | 0X01 | ozone:3.33ppm |
register10data low | 0X4D | |
register11High data | 0X00 | TVOC:99ppb |
register11data low | 0X63 | |
register12High data | 0X02 | air quality:5.55mg/m3 |
register12data low | 0X2B | |
register13High data | 0X00 | H2S:22ppm |
register13data low | 0X16 | |
register14High data | 0X00 | NH3:22ppm |
register14data low | 0X16 | |
register15High data | 0X00 | NO2:8.8ppm |
register15data low | 0X58 | |
register16High data | 0X03 | Odor:8.88ppm |
register16data low | 0X78 | |
register17High data | 0X00 | Dew point temperature:10.5℃ |
register17data low | 0X69 | |
register18High data | 0X00 | Chlorine:2.2ppm |
register18data low | 0X16 | |
register19High data | 0X00 | SO2:2.2ppm |
register19data low | 0X16 | |
register20High data | 0X00 | Civil gas:100ppm |
register20data low | 0X64 | |
CRC16Low | 0X4B | |
CRC16high | 0X8C |
| Precautions for use |
(1)Please check whether the packaging is intact and whether the transmitter model and specifications match the product you purchased.。
(2)Do not connect while the power is on. Only after the wiring is completed and checked are correct can the power be turned on.。
(3)Users should not modify the soldered components and connected wires of this product when it leaves the factory.。
(4)The sensor is a precision device. Users should not disassemble it by themselves when using it,let alone touch the diaphragm to avoid damage to the product.。
(5)Avoid sticky particles from entering the sensor and prevent moisture from affecting the measurement performance.
| Product warranty |
The warranty period of this product is one year. Within twelve months from the date of shipment,our company will be responsible for free repair or replacement of any failure caused by sensor quality problems (non-human damage). After the warranty period,only the cost will be charged.