Campbell Scientific (CSI) CNR1-L Solar Radiation Instrument

- +
Custom Settings Company Homepage More Products

The quotes are provided by Several Partner Companies

  • Prices: Request for a Quote for Further Details
  • Model : CNR1-L
  • Category: Solar Radiation Instrument
  • Brand : Campbell Scientific (CSI)
  • Delivery Time: Request for a Quote for Further Details
  • Manufacturer: Campbell Scientific (CSI)

Products

The CNR1-L net radiometer is manufactured by Kipp and Zonen for applications requiring research-grade performance. The radiometer measures the energy between incident shortwave and longwave infrared radiation and surface reflected shortwave and emitted longwave infrared radiation. It consists of an upward pair of thermometers and a downward complementary pair. Pyranometers and pyrgeometers measure shortwave and far-infrared radiation respectively. All four sensors are calibrated to an identical sensitivity factor. The CNR1-L also includes an RTD for measuring the radiometer’s internal temperature,a 4WPB100 module to interface the RTD with a data logger,and a heater that can be used to prevent condensation.

Product Specifications

Parameter Value Parameter Value
The minimum wavelength sensitivity 7 µV or A /Wm-2 The instrument type Radiometer
Measuring wavelength range 305 to 2800 nm (3050 to 28000 Å) Measurement technology Differential Thermopile
Output options Outputs an analog voltage signal ;Other Working temperature -40 to 158 F (-40 to 70 C)
highly 6.1 inch (155 mm) The weight of the 8.8 lbs (3.99 kg)
Installation type Pole-mounted