Sensor name | Measuring range | Accuracy | Accuracy |
ambient temperature | .-40-123.8℃ | ±0.1℃ | 0.1℃ |
environment humidity | 0~100%RH | ±2%RH | 0.1%RH |
maximum temperature | .-40-123.8℃ | ±0.1℃ | 0.1℃ |
lowest temperature | .-40-123.8℃ | ±0.1℃ | 0.1℃ |
dew point temperature | -40-123.8 | ±0.1℃ | 0.1℃ |
wind speed | 0-60m/s | ±2%(<20m/s),±2%+0.03Ym/s(>20m/s) | 0.1℃ |
2 minutes wind speed | 0-60m/s | ±2%(≤20m/s),±2%+0.03 m/s(>20m/s) | 0.1m/s |
10 minutes wind speed | 0-60m/s | ±2%(≤20m/s),±2%+0.03Vm/s(>20m/s) | 0.1m/s |
wind direction | 0-359° | ±2° | 0.1m/s |
air pressure | 300--1100hPa | ±0.12hPa | 0.1hPa |
Component temperature | .-40~100℃ | ±0.1℃ | 0.1℃ |
hours | 0-24h | ±0.1h | 0.1h |
oblique total radiation | 0~2000/m² | ≤5% | lw/m² |
total horizontal radiation | 0~2000w/m² | ≤5% | 1w/m² |
normal direct radiation | 0-2000w/m² | ≤5% | 1w/m² |
horizontal direct radiation | 0-2000w/m² | ≤5% | lw/m² |
Horizontal scattered radiation | 0~2000%/m² | ≤5% | lw/m |
Tilt total radiation day accumulation | 0-999.9MJ/m² | ≤5% | 0.1M]/m² |
Total horizontal radiation day accumulation | 0-999.9MJ/m² | ≤5% | 0.1MJ/m² |
Daily accumulation of normal direct radiation | 0-999.9MJ/m² | ≤5% | 0.1MJ/m² |
Accumulated horizontal direct radiation days | 0-999.9MJ/m² | ≤5% | 0.1MJ/m² |
Horizontal scattered radiation daily accumulation | 0-999.9MJ/m² | ≤5% | 0.1MJ/m² |
Oblique total radiation monthly accumulation | 0-9999MJ/m² | ≤5% | 1MJ/m² |
Total horizontal radiation monthly accumulation | 09999MJ/m² | ≤5% | 1MJ/m² |
Monthly accumulation of direct normal radiation | 0-9999MJ/m² | ≤5% | 1MJ/m² |
Horizontal direct radiation monthly accumulation | 09999MJ/m² | ≤5% | 1NJ/m² |
Horizontal scattered radiation monthly accumulation | 0~9999MJ/m² | ≤5% | 1NJ/m² |
Tilt total radiation annual accumulation | 0-9999MJ/m² | ≤5% | 1NJ/m² |
Total horizontal radiation annual accumulation | 0-9999WJ/m² | ≤5% | 1NJ/m² |
Annual accumulation of direct normal radiation | 0~9999MJ/m² | ≤5% | 1NJ/m² |
Annual accumulation of horizontal direct radiation | 0~9999MJ/m² | ≤5% | 1MJ/m² |
Horizontal scattered radiation annual vote meter | 0~9999MJ/m² | ≤5% | 1MJ/m² |
There are many factors to consider when selecting the site for a grid-connected photovoltaic power generation system. The site should be built in a place that is unshaded from sunrise to sunset all year round. Based on international observation methods,national observation specifications,power industry standards and many years of rich experience in site selection,environmental monitoring system installation and commissioning,our company provides detailed and professional specification documents to relevant personnel of photovoltaic power stations. Our company has rich experience in serving photovoltaic power plant users at home and abroad for many years,with sufficient sensor inventory,complete production lines,mature instrument and equipment debugging technical capabilities,comprehensive after-sales tracking services,and a fast logistics and transportation system.