LumaSense Technologies, Inc. INNOVA 1314i Gas Instruments
- Prices: Request for a Quote for Further Details
- Model : INNOVA 1314i
- Category: Gas Equipment
- Brand : LumaSense Technologies, Inc.
- Delivery Time: Request for a Quote for Further Details
- Manufacturer: LumaSense Technologies
Products
Characteristics
- Multi Gas Monitoring – up to 5 different gases (+ water vapor) can be measured with excellent sensitivity and accuracy
- Selectively measure a wide variety of gases/vapors,more than 200 compounds have been tested,
- Linear response within a wide dynamic range
- Suitable for long-term monitoring tasks,low operating and maintenance costs: highest stability (low drift) allows calibration to only require 1 -2 times a year,no carrier gas required.
- Direct sampling
- Accurate - compensates for temperature fluctuations,water vapor interference and interference from other known gases
- User-friendly program for calibrating monitors,presenting and analyzing measurement data via pc user interface
- Remote control capability via tcp/ip network interface protocol
- 1409 multi-point sampler can be expanded to 24 positions: the gas monitor can be fully controlled as a system controller Standalone operation
- Optional i/o module (alarm relay,analog output)
- Includes bz7002 calibration Software
- Includes BZ7003 offline software for setting up the gas monitor without connecting it to a PC and downloading data stored in the gas monitor's memory.
- Suitable for permanent monitoring tasks with low operation and maintenance costs: highest stability (low drift) allows calibration only 1-2 times per year,no carrier gas required .
- Remote control function through TCP/IP network interface protocol
LumaSense provides market-quality photoacoustic gas monitoring solutions . The photoacoustic gas monitor INNOVA 1314i is a high-precision,reliable and stable quantitative gas monitor. The 1314i is designed to be extremely versatile and can measure almost any gas that absorbs infrared light at trace levels
Product Specifications
Parameter | Value | Parameter | Value |
---|---|---|---|
Response Time | 150 seconds | The channel number | 24 |
Characteristics of the | Audible or Visual Alarms; Data Logger | According to | Digital |
Working temperature | 41 to 104 F (5 to 40 C) | Working humidity | 80 % |
Installation type | Fixed | Measuring type | Trace |
Type of gas | Toxic; CO2 (1.5 ppm); Refrigerants (0.01 ppm); NxOx (N2O: 0.03 ppm); SF6 (0.006 ppm) (Halothane, Isoflurane, Methyl Methacrylate (MMA)) | The instrument type | Monitor |
application | Continuous Emissions Monitoring; Ambient Air Monitoring; Process Gas | Product category | Gas Instruments |
Sensitivity technology | Infrared |