Yunzhuan IoT Enterprise Wastewater Intelligent Residual Chlorine Sensor Pen Water Quality Detector
- Prices: Request for a Quote for Further Details
- Model : Intelligent residual chlorine sensor for enterprise sewage
- Category: An Ambient Light Sensors
- Brand : Cloud IoT
- Delivery Time: Request for a Quote for Further Details
- Manufacturer: Cloud IoT
Products
one,product description
The intelligent residual chlorine sensor uses the advanced constant voltage principle to measure residual chlorine in water. This method utilizes the application of a stable potential between the polarizing electrode and the reference electrode,and different measured components produce different current intensities under this potential. The instrument calculates the concentration of the component being measured by collecting and analyzing the current signal. The residual chlorine sensor has a simple structure and is easy to clean and replace. At the same time,the electrode does not need to replace the diaphragm and reagents during use,and the maintenance is simple,ensuring the stability,reliability and accuracy of the long-term operation of the instrument.
two,working principle
Intelligent residual chlorine sensorUsing the advanced constant voltage principle,it is used to measure residual chlorine in water bodies. This method utilizes the application of a stable potential between the polarizing electrode and the reference electrode,and different measured components produce different current intensities under this potential. The instrument calculates the concentration of the component being measured by collecting and analyzing the current signal. The residual chlorine sensor has a simple structure and is easy to clean and replace. At the same time,the electrode does not need to replace the diaphragm and reagents during use,and the maintenance is simple,ensuring the stability,reliability and accuracy of the long-term operation of the instrument.
three,Features
lWith automatic temperature compensation;
lOutput standardRs485 (Modbus/RTU protocol) digital signal;
lRs485 signal is conveniently connected to PLC,DCS,industrial control computers,general controllers,paperless notes
lThird-party devices such as instruments or touch screens;
lParameter setting is more convenient and faster;
lCalibration function provides easy and fast calibration;
lReal-time data transmission allows you to obtain timely and accurate data for monitoring water bodies.
Four,Technical Parameters
typeNumber | AMT-YL300 |
Measurement principle | constant voltage method |
Measuring range | 0~2.000mg/L(HClO) |
pointdistinguishRate | 0.001mg/L |
RefinedSpend | ±5% or±0.05mg/L,±0.5℃ |
Calibration function | Intelligent residual chlorine sensorUsing the advanced constant voltage principle,it is used to measure residual chlorine in water bodies. This method utilizes the application of a stable potential between the polarizing electrode and the reference electrode,and different measured components produce different current intensities under this potential. The instrument calculates the concentration of the component being measured by collecting and analyzing the current signal. The residual chlorine sensor has a simple structure and is easy to clean and replace. At the same time,the electrode does not need to replace the diaphragm and reagents during use,and the maintenance is simple,ensuring the stability,reliability and accuracy of the long-term operation of the instrument. Two point calibration |
work pressure | <0.1MPa |
mediumpH range | 4~9pH |
Temperature compensation | Automatic temperature compensation (Pt1000) |
Signal output | RS-485(Modbus/RTU) |
shell material | POM,polytetrafluoroethylene |
Operating temperature | 5~50℃ |
Installation method | Flow cell installation |
rulerinch | 30×233mm |
flowspeed | 30~60L/h |
Response time | <30S |
achievementconsume | |
electricitysource | 12~24VDC |
Protection level | IP68 |
five,Dimensions
The sensor connector isM16-5 core waterproof connector male。
six,Sensor installation
*Note:sensorWhen installing,it cannot be installed upside down or horizontally,at least tiltedInstall at above 15 degrees.
seven,Electrical connections
sensorThe cable is4-core twisted pair shielded wire,wire sequence definition:
lred line—Power cord (12~24VDC)
lblack line—Ground wire (GND)
lblue line—485A
lwhite line—485B
The wiring sequence should be carefully checked before powering on to avoid unnecessary losses caused by wiring errors.
Wiring instructions: Considering that cables are immersed in water (inc seawater) or exposed to the air for a time,all wiring locations are required to be waterproofed,and user cables should have certain anti-corrosion capabilities.
8. Application Market
widely used inIt is used in drinking water treatment plants,plants,drinking water distribution networks,swimming pools,cooling circulating water,water quality treatment projects and other occasions where continuous monitoring of residual chlorine content in aqueous solutions is required.