Yunzhuan IoT Enterprise Wastewater Intelligent Residual Chlorine Sensor Pen Water Quality Detector

- +
Custom Settings Company Homepage More Products

The quotes are provided by Several Partner Companies

  • Prices: Request for a Quote for Further Details
  • Model : Intelligent residual chlorine sensor for enterprise sewage
  • Category: An Ambient Light Sensors
  • Brand : Cloud IoT
  • Delivery Time: Request for a Quote for Further Details
  • Manufacturer: Cloud IoT

Products

one,product description

The intelligent residual chlorine sensor uses the advanced constant voltage principle to measure residual chlorine in water. This method utilizes the application of a stable potential between the polarizing electrode and the reference electrode,and different measured components produce different current intensities under this potential. The instrument calculates the concentration of the component being measured by collecting and analyzing the current signal. The residual chlorine sensor has a simple structure and is easy to clean and replace. At the same time,the electrode does not need to replace the diaphragm and reagents during use,and the maintenance is simple,ensuring the stability,reliability and accuracy of the long-term operation of the instrument.

two,working principle

Intelligent residual chlorine sensorUsing the advanced constant voltage principle,it is used to measure residual chlorine in water bodies. This method utilizes the application of a stable potential between the polarizing electrode and the reference electrode,and different measured components produce different current intensities under this potential. The instrument calculates the concentration of the component being measured by collecting and analyzing the current signal. The residual chlorine sensor has a simple structure and is easy to clean and replace. At the same time,the electrode does not need to replace the diaphragm and reagents during use,and the maintenance is simple,ensuring the stability,reliability and accuracy of the long-term operation of the instrument.

three,Features

lWith automatic temperature compensation

lOutput standardRs485 (Modbus/RTU protocol) digital signal

lRs485 signal is conveniently connected to PLC,DCS,industrial control computers,general controllers,paperless notes

lThird-party devices such as instruments or touch screens

lParameter setting is more convenient and faster

lCalibration function provides easy and fast calibration

lReal-time data transmission allows you to obtain timely and accurate data for monitoring water bodies.

Four,Technical Parameters

typeNumber

AMT-YL300

Measurement principle

constant voltage method

Measuring range

0~2.000mg/L(HClO)

pointdistinguishRate

0.001mg/L

RefinedSpend

±5% or±0.05mg/L,±0.5

Calibration function

Intelligent residual chlorine sensorUsing the advanced constant voltage principle,it is used to measure residual chlorine in water bodies. This method utilizes the application of a stable potential between the polarizing electrode and the reference electrode,and different measured components produce different current intensities under this potential. The instrument calculates the concentration of the component being measured by collecting and analyzing the current signal. The residual chlorine sensor has a simple structure and is easy to clean and replace. At the same time,the electrode does not need to replace the diaphragm and reagents during use,and the maintenance is simple,ensuring the stability,reliability and accuracy of the long-term operation of the instrument.

Two point calibration

work pressure

0.1MPa

mediumpH range

4~9pH

Temperature compensation

Automatic temperature compensation (Pt1000)

Signal output

RS-485(Modbus/RTU)

shell material

POM,polytetrafluoroethylene

Operating temperature

5~50

Installation method

Flow cell installation

rulerinch

30×233mm

flowspeed

30~60L/h

Response time

<30S

achievementconsume

electricitysource

12~24VDC

Protection level

IP68

five,Dimensions

The sensor connector isM16-5 core waterproof connector male

six,Sensor installation

*Note:sensorWhen installing,it cannot be installed upside down or horizontally,at least tiltedInstall at above 15 degrees.

seven,Electrical connections

sensorThe cable is4-core twisted pair shielded wire,wire sequence definition:

lred linePower cord (12~24VDC)

lblack lineGround wire (GND)

lblue line485A

lwhite line485B

The wiring sequence should be carefully checked before powering on to avoid unnecessary losses caused by wiring errors.

Wiring instructions: Considering that cables are immersed in water (inc seawater) or exposed to the air for a time,all wiring locations are required to be waterproofed,and user cables should have certain anti-corrosion capabilities.

8. Application Market

widely used inIt is used in drinking water treatment plants,plants,drinking water distribution networks,swimming pools,cooling circulating water,water quality treatment projects and other occasions where continuous monitoring of residual chlorine content in aqueous solutions is required.