Maidesheng China MDS1028 signal conditioning

- +
Custom Settings Company Homepage More Products

The quotes are provided by Several Partner Companies

  • Prices: Request for a Quote for Further Details
  • Model : MDS1028
  • Category: Temperature Sensors
  • Brand : Mai Desheng China
  • Delivery Time: Request for a Quote for Further Details
  • Manufacturer: Mai Desheng China

Products

Overview

MDS1028is a general-purpose intelligent two-wire temperature transmitter that can be used to detect thermal resistance,thermocouple,millivolt and resistance signals. The user canset the input type and range through PC configuration,and has excellent performance and reliability. performance and anti-interference ability; widely suitable for various industrial applications.

?

characteristic

Thermal resistance and thermocouple are common and can be configured throughPCconfiguration

Input and output electromagnetic isolation

Ultra-low operating voltage,supports higher load resistance

Built-in cold junction compensation

●24-bit digital conversion combined with digital linearization technology provides higher accuracy

Vacuum potting process,earthquake-proof and moisture-proof

Electromagnetic compatibility complies withENandEN21

Suitable for installation in standard junction box (DIN B)

?

Input signal and basic error

?

MDS1028

input range

basic error

input type

Measuring range

Minimum range

absolute error

Range error

hot

electricity

block

Pt 100

-200850

50

±0.4

±0.2%FS

Pt 1000

-200850

50

±0.6

±0.2%FS

Cu50

-50150

50

±0.4

±0.2%FS

Cu100

-50150

50

±0.4

±0.2%FS

Ni1000

-60250

50

±0.6

±0.2%FS

linear resistor

0-400Ω

20Ω

0.2Ω

±0.2%FS

0-4000Ω

100Ω

0.5Ω

±0.2%FS

hot

electricity

I

Ktype

-2001372

50

±1

±0.2%FS

Stype

01768

200

±3

±0.2%FS

TypeE

-2001000

50

±1

±0.2%FS

TypeB

1001820

200

±3

±0.2%FS

TypeR

01768

200

±3

±0.2%FS

Ttype

-200400

50

±1

±0.2%FS

Jtype

-2001200

50

±1

±0.2%FS

Ntype

-2001300

50

±1.5

±0.2%FS

millivolt voltage

-10100mV

10mV

40uV

±0.2%FS

Remarks:1.The ambient temperature during accuracy testingis 25±2,24Vpower supply voltage,250ohm load;

2.The actual error during application is the maximum value of the absolute error and the range error.

?

Working power supply

Power supply voltage:8~36V

Allowable power ripple:Vpp<1.0%

Power supply voltage influence:0.002%?FS?/V

insulation

Insulation resistance:500MΩ(500VAC)

Dielectric strength:1500VAC/60s(leakage current less than1.0mA)

enter

Input signals: RTD,thermocouple,millivolt and resistance signals

For details,seeInput Signal and Basic Error

output

2-wire4-20mAoutput,the output signal is linearly related to the input signal

Linear output range:3.9 mAI21.0mA

Fault low alarm value:? 3.5~3.8mA?? (factory default3.8mA,user configurable)

High fault alarm value:21.0~22.0mA ?? (factory default22mA,user configurable)

Output ripple:Vpp20mV

basic error

Basic error:±0.2 %?FS(seeinput signal and basic error for details)

temperature drift

Temperature drift:±0.01%?FS/

maximum load

Maximum load resistance= ? (supply voltage- 8V) /0.022A.

When the supply voltage is24V,the maximum load is727Ω?

?

Thermal resistance related parameters

Maximum wire resistance allowed for a single sensor cable: 10Ω
Effect of sensor cable resistance: 0.05Ω/10Ω
Thermal resistor excitation current: ≤250uA
Thermal resistance connection mode: two-wire or three-wire input,user configurable,default three-wire system

Thermocouple related parameters

Cold junction compensation method: internal or external compensation,user configurable,factory default internal compensation Internal compensation accuracy: ≤0.5℃ (0~70℃) ≤1℃ (-40~85℃)

Damping parameters

0~60s,user configurable,factory default is 0.0s

Start Time

Performance within the technical specifications will be achieved within 5 minutes after the transmitter is powered on.

Response time (T90)

When the damping parameter is 0,the response time is ≤1s