Kaisheng Power Vacuum Brake Booster Pressure Sensor Pressure Sensor
- Prices: Request for a Quote for Further Details
- Model : Vacuum brake booster pressure sensor
- Category: Pressure Sensors
- Brand : Kaisheng Power
- Delivery Time: Request for a Quote for Further Details
- Manufacturer: Kaisheng Power
Products
Product Features and Benefits Feature and benefits
VBS can provide a signal
The VBS provides pressure output
The pressure sensing element and the absolute pressure signal inside the vacuum brake booster processed by the chip
Internal absolute pressure signal of vacuum brake booster processed by pressure sensor and chip
Single-chip solution,the circuit unit is mounted using SMT technology
Single chip solution,SMT for EMA fabrication process
Utilizes steel ball technology for vent sealing,laser marking for better traceability
Steel ball for vent hole sealing,laser marking for better traceability
According to customer requirements,multiple measuring ranges are available (10-115,13.3-106.7 kpa abs)
Different pressure ranges are available on customer request
Product function Application
This sensor can monitor the pressure in the vacuum booster,convert the pressure into an electrical signal,and output it to the start-stop system,thereby achieving the purpose of saving energy consumption.
The sensor can monitor the pressure in the vacuum booster,convert the pressure into electrical signal and output it to the Stop-Start System,so as to save energy.
Technical parameters Functional Characteristics
parameterPARAMETER | symbolNOTE | minimum valueMIN. | RatingNOM. | maximum valueMAX. | unitUNITS |
Operating temperature | T | -40 | 120 | ℃ | |
Pressure measuring range | P | 13.3 | 106.7 | kPa | |
voltage | Vcc | 4.87 | 5.12 | 5.37 | V |
Supply current | Icc | 8 | 10 | Ma | |
Output load current | IL | -1 | 1 | mA | |
Load Resistance | Rpull-down | 100 | kΩ | ||
Rated output voltage | Vout | 10 | 90 | %Vcc | |
Output voltage upper limit | VCL-HI | 4.62 | 4.65 | 4.68 | V |
Output voltage lower limit | VCL-LO | 0.42 | 0.45 | 0.48 | V |
Overall accuracy error | Err | 2.2 | kPa | ||
pressure response time | Final output voltage from 0% to 90% | 5 | ms |