Introduction
? ? ? This XKCON carbon monoxide detector (product model: XKCON-700-CO) is an explosion-proof carbon monoxide gas detection instrument developed by our company in accordance with industrial design standards. It can be directly installed in Zone 1 and hazardous areas Zone 2 use.
1. Functional features??
1. Use imported carbon monoxide sensor detection probe, with high precision and excellent long-term stability; ? ? ?
2. Supports 0~2000ppm measurement range; ? ? ?
3. Built-in temperature compensation, excellent environmental adaptability; ? ? ?
4. DC12~30V wide voltage power supply; ? ? ?
5. Supports RS485, 4-20mA, and HART multiple communication methods to choose from; ? ? ?
6. The equipment uses aluminum alloy explosion-proof shell, which is strong and durable; ? ? ?
7. Support 24-hour continuous online monitoring; ? ? ?
8. Automatically perform zero-point calibration in the air to eliminate false alarms; ? ? ?
9. Comes with multiple cable ports to facilitate on-site wiring construction.
2. Design standards??
GB 50493-2019 "Design Specifications for Detection and Alarm of Combustible and Toxic Gases in Petrochemical Enterprises" ? ? ?
GB 12358-2006 "General technical requirements for ambient gas detection and alarm devices in workplaces"
3. Implementation standards? ?
GB 3836.1-2010 "Electrical equipment for explosive gas environments Part 1: General requirements" ? ? ?
GB 3836.2-2010 "Electrical equipment for explosive gas environments Part 2: Flameproof type "d"" ? ? ?
GB 12358-2006 "General Technical Requirements for Ambient Gas Detection and Alarm Instruments in Workplaces" ? ? ?
GBZ2.1-2007 "Occupational Exposure Limits for Hazardous Factors in the Workplace" ? ? ?
GB 4208-2008 "Enclosure Protection Level (IP Code)" ? ? ?
GB 12476.1-2013 Electrical equipment for combustible dust environments Part 1: General requirements? ? ?
GB 12476.1-2013 Electrical equipment for combustible dust environments Part 5: Shell protection type "tD"
4. Application? ?
? ? ? Warehouses, cable and cosmetics factories, food factories, wineries, laboratories, coal mines, substations and other places.
5. Product parameters
?Operating voltage 24V DC
?Measurement range 0~2000ppm
?Resolution 1ppm
?Linear error≤±2%
?Gas production method is natural diffusion type
?Design life 2 to 5 years
?Transmission method RS485/4-20mA/HART
?No display function
?Large shell
?Operating temperature 0℃~+50℃
?Operating humidity 10~95%RH
?Working pressure 86~106Kpa
?Explosion protection level Exd IICT6 Gb/Ex tD A21 IP66 T8
?Protection level IP66
Product Specifications
Parameter | Value | Parameter | Value |
---|---|---|---|
Type of gas | Carbon monoxide (CO) |