  • Sensidyne 7013276-1

    Total of 23 Product Data

    Click to View
    7013276-1
    • Monitoring gas quantity:Multi
    • The electrical output:Analog Current;Current
    • According to:Digital
    • Working temperature:-22 to 131 F (-30 to 55 C)
    • Working humidity:5 to 95 %
    • Measuring type:%LEL or %LFL; %Volume; Trace
    • Type of gas:Toxic; Combustible
    • Product category:Gas Transmitters
  • AMETEK Land 9100

    Total of 1 Product Data

    Click to View
    9100
    • Monitoring gas quantity:Single
    • Detection technology:Infrared
    • The electrical output:Current
    • According to:Digital
    • Working temperature:-22 to 131 F (-30 to 55 C)
    • Measuring type:Trace
    • Type of gas:Toxic; CO (0-10000 ppm)
    • Product category:Gas Transmitters
  • GDK7DII
    • Monitoring gas quantity:Single
    • Detection technology:Electrochemical
    • Measuring type:Trace
    • Type of gas:Toxic; NH3 (0-75 ppm); AsH3 (0-0.2 ppm); Br2 (0-1 ppm); Cl2 (0-1.5 ppm); B2H6 (0-.03 ppm); F (0-30 ppm); HCl (0-15 ppm); HF (0-9 ppm); H2S (0-1 ppm); NO2 (0-15 ppm); O3 (0-0.6 ppm); PH3 (0-1 ppm); SiH4 (0-15 ppm) (Many Others)
    • Product category:Gas Transmitters
  • 2-Wire smarter Gas Detectors - Tox-Array 2102 - TA-2102 smarter
    • Monitoring gas quantity:Multi
    • Detection technology:Catalytic; Electrochemical; Infrared; PID; Semiconductor; Solid State MOS
    • Response Time:30 seconds
    • Characteristics of the:Audible or Visual Alarms; Hazardous Environment; Intrinsically Safe; Self Calibration
    • The electrical output:Current
    • According to:Analog; Digital
    • Working temperature:-13 to 122 F (-25 to 50 C)
    • Working humidity:0 to 95 %
    • Measuring type:%Volume; Trace
    • Type of gas:Toxic; NH3 (0-200ppm); AsH3 (0.00-1.00ppm); Br2 (0.0-5.0ppm); CO (0-200ppm); Cl2 (0.0-5.0ppm); ClO2 (0.0-5.0ppm); B2H6 (0.00-1.00ppm); F (0.0-5.0ppm); GeH4 (0.00-5.00ppm); HCl (0.0-20.0ppm); HCN (0-50ppm); HF (0.0-20.0ppm); H2Se (0.20-1.00ppm); H2S (0-50ppm); NO (0-100ppm); NO2 (0.0-20.0ppm); O2 (0.0-25.0%LEL); O3 (0.0-20.0ppm); PH3 (0.00-1.00ppm); SiH4 (0-50ppm); SO2 (0.0-20.0ppm) (C3H3N, AsF5, BCl3, BF3, N2H4, HI, HBr)
    • The channel number:1
    • Product category:Gas Transmitters
  • Vaisala AQT410

    Total of 6 Product Data

    Click to View
    AQT410
    • Monitoring gas quantity:Multi
    • Detection technology:Electrochemical
    • Characteristics of the:Temperature Measurement
    • Working temperature:-22 to 122 F (-30 to 50 C)
    • Working humidity:15 to 95 %
    • Measuring type:Trace
    • Type of gas:CO; H2S ; NO; NO2 ; O3 ; SO2
    • Product category:Gas Transmitters
  • CARLO GAVAZZI ESCOxxxx

    Total of 4 Product Data

    Click to View
    ESCOxxxx
    • Monitoring gas quantity:Single
    • Detection technology:Electrochemical
    • The electrical output:Voltage; Current
    • Working temperature:32 to 122 F (0 to 50 C)
    • Working humidity:5 to 95 %
    • Measuring type:Trace
    • Type of gas:Toxic; CO (300ppm to 500ppm)
    • Product category:Gas Transmitters
  • E+E Elektronik EE800

    Total of 1 Product Data

    Click to View
    EE800
    • Monitoring gas quantity:Single
    • Detection technology:Infrared
    • Characteristics of the:Temperature Measurement
    • The electrical output:Voltage; Current
    • According to:Digital
    • Working temperature:-22 to 131 F (-30 to 55 C)
    • Working humidity:10 to 90 %
    • Measuring type:Trace
    • Type of gas:CO2
    • Product category:Gas Transmitters