Filter Criteria

Sound Field Type

Frequency Response

Microphone Sensitivity

Dynamic Range

Impedance

Diameter

Thickness/Height

Feature

Polarization

Range Of Working Temperature

Working Humidity Range

%

Filter Criteria

  • PCB Piezotronics 377A06

    Total of 27 Product Data

    Click to View
  • 567M7
    • Dynamic Scope:191 dB re 20µPa
    • Frequency response range:5.2 to 5000 Hz
    • Sound field type:Pressure Field
    • Working temperature:-10 to 500 F (-23 to 260 C)
    • Humidity range:0 to 100 %
    • The actual size:1.38 inch (34.92 mm)
    • The thickness/height:2.87 inch (72.9 mm)
    • Accredited institution:MIL-C-5015
    • application:Industrial
    • Nominal size:Other; 1.375
    • Product category:Measurement Microphones
  • NTi Audio AG M2010

    Total of 7 Product Data

    Click to View
    M2010
    • The sensitivity:35 mV/Pa (241313 mV/psi)
    • Dynamic Scope:24 to 145 dB re 20µPa
    • Frequency response range:20 to 20000 Hz
    • Polarization mode:Prepolarized Electret
    • impedance:50 to 100 ohms
    • Working temperature:14 to 122 F (-10 to 50 C)
    • application:Industrial Manufacturing Quality Control R&D
    • Nominal size:1/2
    • Product category:Measurement Microphones
  • Model 2510
    • Dynamic Scope:100 to 180 dB re 20µPa
    • Frequency response range:1000 to 10000 Hz
    • Sound field type:Pressure Field
    • Working temperature:-67 to 500 F (-55 to 260 C)
    • The actual size:0.8150 inch (20.7 mm)
    • The thickness/height:1.36 inch (34.54 mm)
    • application:Charge Amplifiers
    • Nominal size:1
    • Product category:Measurement Microphones
  • MP471S 1/4 inch pressure field microphone
    • Product categories:Games pre-polarization microphone - pressure and diffusion
    • Conform to the standard:IEC 61094-4 Type WS3P
    • Intelligent sensor (TEDS):Comply with the IEEE 1451.4 (default v0.9, optional v1.0)
    • Equalizing hole:The lateral pressure
    • Contains no shielding:Φ6.35 × 9.4
    • Using the temperature range:-30 to 80 C
    • Use the humidity range:0 to 98 %RH
    • Dynamic Scope:56 to 170 dBA to dB
    • Pressure coefficient (dB/kPa):-0.007 250Hz
    • Including shielding:Φ7 × 10.2
    • Sound field type:Pressure field
    • Open circuit sensitivity @250 Hz (±3 dB):0.5 mV/Pa
    • The loudest level:Distortion of 170 (3%) the dB
    • Background noise:56 dBA
    • Polarization voltage:0 V (pre-polarization)
    • Temperature coefficient (dB/°C):-0.02 250Hz
    • Humidity influence:<0.1
    • capacitance:6 pF
    • The diameter of:1/4
    • Equivalent front cavity volume@250 Hz:0.3 mm3
    • level:Level 1 IEC 61672
    • Connection thread:5.7mm-60UNS
    • Apply preamplifier:MA401
    • The weight of the:1.7 g
    • Frequency response:-8202640-37 to 8202640-37
  • noise sensor

    Noise Sensor

  • FEBUS A1-R

    Distributed fiber optic acoustic sensing system FEBUS A1-R

  • SKC MP40

    Total of 3 Product Data

    Click to View
    MP40
    • The sensitivity:50 mV/Pa
    • Dynamic Scope:30-126 dB re 20µPa
    • Frequency response range:20-20000 Hz
    • Sound field type:Free field;
    • Polarization mode:Pre-polarization electret
    • The actual size:1/4 inch
  • infrasound sensor

    Infrasound monitoring sensor

  • XKCON XKCON-EUS400-01

    Total of 1 Product Data

    Click to View
    XKCON-EUS400-01

    XKCON XKCON-EUS400-01 measurement microphone

Filter Criteria

Filter Criteria

Sound Field Type

Frequency Response

Microphone Sensitivity

Dynamic Range

Impedance

Diameter

Thickness/Height

Feature

Polarization

Range Of Working Temperature

Working Humidity Range

%

}