  • ADS430
    • precision:0.1000 to 10 % FS
    • Scope of work pressure:150 to 300 psi (106 to 211 m H2O)
    • Oxygen content range:0.0 to 50 ppm
    • Response Time:45 to 60 seconds
    • Working temperature range:32 to 122 F (0.0 to 50 C)
    • The maximum length:8 inch (203 mm)
    • The largest diameter/width:1.85 inch (46.99 mm)
    • The installation:In-Line
    • Product category:Dissolved Oxygen Sensors
  • High Performance Dissolved Oxygen (DO) Sensor - Thornton M300 Series
    • precision:1 % FS
    • Scope of work pressure:0.0 to 72.52 psi (0.0 to 51.04 m H2O)
    • Oxygen content range:0.0 to 10 ppm
    • Response Time:90 seconds
    • Working temperature range:32 to 140 F (0.0 to 60 C)
    • The maximum length:4.28 inch (109 mm)
    • The largest diameter/width:1.8 inch (45.72 mm)
    • The installation:Flow Thru
    • The cell type:Polarographic
    • Characteristics of the:Disposable Membrane Cap; Temperature Compensated
    • Product category:Dissolved Oxygen Sensors
  • ADS430
    • precision:0.1000 to 10 % FS
    • Scope of work pressure:150 to 300 psi (106 to 211 m H2O)
    • Oxygen content range:0.0 to 50 ppm
    • Response Time:45 to 60 seconds
    • Working temperature range:32 to 122 F (0.0 to 50 C)
    • The maximum length:8 inch (203 mm)
    • The largest diameter/width:1.85 inch (46.99 mm)
    • The installation:In-Line
    • Product category:Dissolved Oxygen Sensors
  • CS511-L
    • precision:2 % FS
    • Scope of work pressure:0.0 to 100 psi (0.0 to 70.38 m H2O)
    • Oxygen content range:0.5000 to 20 ppm
    • Minimum flow:5.08 cm/sec (2 in/sec)
    • Response Time:300 seconds
    • Working temperature range:32 to 122 F (0.0 to 50 C)
    • The maximum length:7 inch (178 mm)
    • The largest diameter/width:2.25 inch (57.15 mm)
    • The installation:Flow Thru
    • The cell type:Galvanic
    • Characteristics of the:Disposable Membrane Cap; Built-in Temperature Sensor; Temperature Compensated
    • Product category:Dissolved Oxygen Sensors
  • Model 499ADO
    • Scope of work pressure:0.0 to 65 psi (0.0 to 45.75 m H2O)
    • Oxygen content range:0.0 to 20 ppm
    • Response Time:25 seconds
    • Working temperature range:32 to 122 F (0.0 to 50 C)
    • The maximum length:5.63 inch (143 mm)
    • The largest diameter/width:0.7500 to 1 inch (19.05 to 25.4 mm)
    • The installation:In-Line
    • The cell type:Galvanic
    • Characteristics of the:Temperature Compensated
    • Product category:Dissolved Oxygen Sensors
  • miniDOT Clear Logger
    • precision:-5 to 5 % FS
    • Oxygen content range:0.0 to 150 ppm
    • Working temperature range:32 to 95 F (0.0 to 35 C)
    • The installation:Hand Held or Portable
    • The cell type:Galvanic
    • Characteristics of the:Built-in Temperature Sensor
    • Product category:Dissolved Oxygen Sensors
  • A-87.230.051
    • precision:0.3000 % FS
    • Scope of work pressure:42 psi (29.56 m H2O)
    • Oxygen content range:20 ppm
    • Response Time:180 seconds
    • Working temperature range:59 F (15 C)
    • The maximum length:6.14 inch (156 mm)
    • The largest diameter/width:1.26 inch (32 mm)
    • The installation:In-Line
    • Characteristics of the:Temperature Compensated
    • Product category:Dissolved Oxygen Sensors
  • Oxymax COS 22&22D
    • Scope of work pressure:174 psi (122 m H2O)
    • Oxygen content range:0.0100 to 60 ppm
    • Minimum flow:2.13 to 10.06 cm/sec (0.8400 to 3.96 in/sec)
    • Response Time:60 seconds
    • Working temperature range:23 to 175 F (-5 to 79.44 C)
    • The maximum length:4.72 to 16.54 inch (120 to 420 mm)
    • The largest diameter/width:0.4724 inch (12 mm)
    • The installation:In-Line
    • The cell type:Galvanic
    • Characteristics of the:Built-in Temperature Sensor; Temperature Compensated
    • Product category:Dissolved Oxygen Sensors
  • Hamilton 237450

    Total of 37 Product Data

    Click to View
    237450
    • Scope of work pressure:0.0 to 58.02 psi (0.0 to 40.83 m H2O)
    • Oxygen content range:0.0100 to 40 ppm
    • Minimum flow:3 cm/sec (1.18 in/sec)
    • Response Time:60 seconds
    • Working temperature range:32 to 266 F (0.0 to 130 C)
    • The maximum length:4.72 inch (120 mm)
    • The largest diameter/width:0.4724 inch (12 mm)
    • The installation:The Hand by the or Portable/handheld/Portable
    • The cell type:Polarographic
    • Characteristics of the:Built-in Temperature Sensor
    • Product category:Dissolved Oxygen Sensors
  • 12
    • Working temperature range:? to 176 F (? to 80 C)
    • The maximum length:5.91 inch (150 mm)
    • The largest diameter/width:0.4724 inch (12 mm)
    • The cell type:Polarographic
    • Product category:Dissolved Oxygen Sensors
Filter Criteria

Filter Criteria

Electrolytic Cell Type

Oxygen Content Range

Accuracy

% FS

Minimum Flow

Response Time

The Maximum Length

Appearance And Installation Options

Maximum Diameter/Width

Range Of Working Temperature

Working Pressure Range

}