Filter Criteria
Dissolved Oxygen Sensors
-
Mettler-Toledo High Performance Dissolved Oxygen (DO) Sensor - Thornton M300 Series
Total of 7 Product Data
Click to View- precision:1 % FS
- Scope of work pressure:0.0 to 72.52 psi (0.0 to 51.04 m H2O)
- Oxygen content range:0.0 to 10 ppm
- Response Time:90 seconds
- Working temperature range:32 to 140 F (0.0 to 60 C)
- The maximum length:4.28 inch (109 mm)
- The largest diameter/width:1.8 inch (45.72 mm)
- The installation:Flow Thru
- The cell type:Polarographic
- Characteristics of the:Disposable Membrane Cap; Temperature Compensated
- Product category:Dissolved Oxygen Sensors
-
Rosemount / Emerson Model 499ADO
Total of 1 Product Data
Click to View- Scope of work pressure:0.0 to 65 psi (0.0 to 45.75 m H2O)
- Oxygen content range:0.0 to 20 ppm
- Response Time:25 seconds
- Working temperature range:32 to 122 F (0.0 to 50 C)
- The maximum length:5.63 inch (143 mm)
- The largest diameter/width:0.7500 to 1 inch (19.05 to 25.4 mm)
- The installation:In-Line
- The cell type:Galvanic
- Characteristics of the:Temperature Compensated
- Product category:Dissolved Oxygen Sensors
-
Precision Measurement Engineering, Inc. miniDOT Clear Logger
Total of 1 Product Data
Click to View -
SWAN Analytical A-87.230.051
Total of 2 Product Data
Click to View- precision:0.3000 % FS
- Scope of work pressure:42 psi (29.56 m H2O)
- Oxygen content range:20 ppm
- Response Time:180 seconds
- Working temperature range:59 F (15 C)
- The maximum length:6.14 inch (156 mm)
- The largest diameter/width:1.26 inch (32 mm)
- The installation:In-Line
- Characteristics of the:Temperature Compensated
- Product category:Dissolved Oxygen Sensors
-
Endress+Hauser ( E+H ) Oxymax COS 22&22D
Total of 4 Product Data
Click to View- Scope of work pressure:174 psi (122 m H2O)
- Oxygen content range:0.0100 to 60 ppm
- Minimum flow:2.13 to 10.06 cm/sec (0.8400 to 3.96 in/sec)
- Response Time:60 seconds
- Working temperature range:23 to 175 F (-5 to 79.44 C)
- The maximum length:4.72 to 16.54 inch (120 to 420 mm)
- The largest diameter/width:0.4724 inch (12 mm)
- The installation:In-Line
- The cell type:Galvanic
- Characteristics of the:Built-in Temperature Sensor; Temperature Compensated
- Product category:Dissolved Oxygen Sensors
-
Hamilton 243560
Total of 2 Product Data
Click to View- Scope of work pressure:-14.5 to 174 psi (-10.21 to 122 m H2O)
- Oxygen content range:0.0 to 2 ppm
- Response Time:20 to 90 seconds
- Working temperature range:14 to 284 F (-10 to 140 C)
- The maximum length:4.72 inch (120 mm)
- The largest diameter/width:0.4724 inch (12 mm)
- The installation:In-Line
- Characteristics of the:Built-in Temperature Sensor
- Product category:Dissolved Oxygen Sensors
-
Analytical Sensors & Instruments (ASI) 12
Total of 5 Product Data
Click to View -
HF scientific AdvantEDGE Dissolved Oxygen Electrode Sensor
Total of 2 Product Data
Click to View -
Guangzhou Jinyuan Technology ODO8000
Total of 1 Product Data
Click to View -
Shuide Technology optical dissolved oxygen
Total of 2 Product Data
Click to View