Filter Criteria

Appearance And Installation Options

Electrode Structure

Connector Type

Electrode Material

ORP Range

ORP Accuracy

±% Full Scale

Response Time

Reference Plan Options

Feature

Operating Temperature

Working Pressure Range

Filter Criteria

Oxidation Reduction Potential (orp) Electrode

  • ORP-4580
    • work pressure:0.0 to 100 psi (0.0 to 70.38 m H2O)
    • Response Time:5 seconds
    • Reference solution options:Refillable
    • Joint type:Double Junction
    • Working temperature:32 to 122 F (0.0 to 50 C)
    • Electrode materials:Glass
    • The electrode structure:Combination
    • Appearance and installation options:In-Line
    • Product category:Oxidation Reduction Potential (ORP) Electrodes
  • Dual-Membrane pH Electrode for Chlor-Alkali Processes - InPro4850i Series
    • work pressure:0.0 to 188 psi (0.0 to 132 m H2O)
    • Reference solution options:Sealed
    • Characteristics of the:Measures pH; Submersible / Water Resistant
    • Joint type:Single Junction
    • Working temperature:14 to 248 F (-10 to 120 C)
    • Electrode materials:Glass
    • Appearance and installation options:In-Line
    • Product category:Oxidation Reduction Potential (ORP) Electrodes
    • Diameter/width:0.4700 inch (11.94 mm)
    • The length of the:4.72 to 16.73 inch (120 to 425 mm)
    • The reference element:Silver-Silver Chloride (Ag Ag/Cl)
  • PCE-228
    • ORP scope:-1999 to 1999 millivolts
    • Characteristics of the:Temperature Sensor; Measures pH
    • Working temperature:32 to 122 F (0.0 to 50 C)
    • Electrode materials:Epoxy or Polymer
    • Appearance and installation options:Hand Held or Portable
    • Product category:Oxidation Reduction Potential (ORP) Electrodes
  • Sartorius PY-R01

    Total of 1 Product Data

    Click to View
    PY-R01
    • Reference solution options:Sealed
    • Working temperature:23 to 212 F (-5 to 100 C)
    • Electrode materials:Glass
    • The electrode structure:Combination
    • Appearance and installation options:Hand Held or Portable
    • Product category:Oxidation Reduction Potential (ORP) Electrodes
  • CSIM11-ORP-L
    • ORP accuracy:0.1000 ±% Full Scale
    • work pressure:0.0 to 30 psi (0.0 to 21.11 m H2O)
    • ORP scope:-700 to 1100 millivolts
    • Response Time:10 seconds
    • Reference solution options:Refillable
    • Characteristics of the:Submersible or Water Resistant
    • Joint type:Single Junction
    • Working temperature:32 to 176 F (0.0 to 80 C)
    • Electrode materials:Glass
    • The electrode structure:Combination
    • Appearance and installation options:In-Line
    • Product category:Oxidation Reduction Potential (ORP) Electrodes
  • Model 3900
    • work pressure:0.0 to 115 psi (0.0 to 80.64 m H2O)
    • ORP scope:-1500 to 1500 millivolts
    • Reference solution options:Sealed
    • Characteristics of the:Temperature Sensor (optional feature); Temperature Compensated; Measures pH
    • Joint type:Double Junction
    • Working temperature:14 to 212 F (-10 to 100 C)
    • Electrode materials:Glass
    • Appearance and installation options:In-Line
    • Product category:Oxidation Reduction Potential (ORP) Electrodes
    • The length of the:8.63 inch (219 mm)
    • Diameter/width:0.7500 to 1 inch (19.05 to 25.4 mm)
  • 12mm Combination Ph&ORP Sensor
    • ORP scope:-1500 to 1500 millivolts
    • Characteristics of the:Measures pH
    • Product category:Oxidation Reduction Potential (ORP) Electrodes
  • A-87.427.010
    • work pressure:0.0 to 29.01 psi (0.0 to 20.41 m H2O)
    • ORP scope:-400 to 1200 millivolts
    • Reference solution options:Sealed
    • Characteristics of the:Measures pH
    • Joint type:Single Junction
    • Working temperature:32 to 122 F (0.0 to 50 C)
    • Electrode materials:Epoxy or Polymer
    • The electrode structure:Single Cell or No Reference
    • Appearance and installation options:Plug PG 13,5 ;Other
    • Diameter/width:0.4724 inch (12 mm)
    • Product category:Oxidation Reduction Potential (ORP) Electrodes
    • The length of the:5.94 inch (151 mm)
  • Ceragel CPS 72 &72D
    • work pressure:0.0 to 145 psi (0.0 to 102 m H2O)
    • ORP scope:-1500 to 1500 millivolts
    • Reference solution options:Sealed
    • Characteristics of the:Food or Sanitary; Submersible or Water Resistant
    • Joint type:Double Junction
    • Working temperature:5 to 275 F (-15 to 135 C)
    • Electrode materials:Glass
    • The electrode structure:Combination
    • Appearance and installation options:In-Line
    • Diameter/width:0.4700 inch (11.94 mm)
    • Product category:Oxidation Reduction Potential (ORP) Electrodes
    • The length of the:4.72 to 14.17 inch (120 to 360 mm)
Filter Criteria

Filter Criteria

Appearance And Installation Options

Electrode Structure

Connector Type

Electrode Material

ORP Range

ORP Accuracy

±% Full Scale

Response Time

Reference Plan Options

Feature

Operating Temperature

Working Pressure Range

}