Filter Criteria
Oxidation Reduction Potential (orp) Electrode
-
OMEGA Engineering ORP-4580
Total of 12 Product Data
Click to View- work pressure:0.0 to 100 psi (0.0 to 70.38 m H2O)
- Response Time:5 seconds
- Reference solution options:Refillable
- Joint type:Double Junction
- Working temperature:32 to 122 F (0.0 to 50 C)
- Electrode materials:Glass
- The electrode structure:Combination
- Appearance and installation options:In-Line
- Product category:Oxidation Reduction Potential (ORP) Electrodes
-
Mettler-Toledo Dual-Membrane pH Electrode for Chlor-Alkali Processes - InPro4850i Series
Total of 16 Product Data
Click to View- work pressure:0.0 to 188 psi (0.0 to 132 m H2O)
- Reference solution options:Sealed
- Characteristics of the:Measures pH; Submersible / Water Resistant
- Joint type:Single Junction
- Working temperature:14 to 248 F (-10 to 120 C)
- Electrode materials:Glass
- Appearance and installation options:In-Line
- Product category:Oxidation Reduction Potential (ORP) Electrodes
- Diameter/width:0.4700 inch (11.94 mm)
- The length of the:4.72 to 16.73 inch (120 to 425 mm)
- The reference element:Silver-Silver Chloride (Ag Ag/Cl)
-
PCE Instruments PCE-228
Total of 2 Product Data
Click to View -
Sartorius PY-R01
Total of 1 Product Data
Click to View -
Inspector Tools FL3475075
Total of 1 Product Data
Click to View -
Campbell Scientific (CSI) CSIM11-ORP-L
Total of 1 Product Data
Click to View- ORP accuracy:0.1000 ±% Full Scale
- work pressure:0.0 to 30 psi (0.0 to 21.11 m H2O)
- ORP scope:-700 to 1100 millivolts
- Response Time:10 seconds
- Reference solution options:Refillable
- Characteristics of the:Submersible or Water Resistant
- Joint type:Single Junction
- Working temperature:32 to 176 F (0.0 to 80 C)
- Electrode materials:Glass
- The electrode structure:Combination
- Appearance and installation options:In-Line
- Product category:Oxidation Reduction Potential (ORP) Electrodes
-
Rosemount / Emerson Model 3900
Total of 12 Product Data
Click to View- work pressure:0.0 to 115 psi (0.0 to 80.64 m H2O)
- ORP scope:-1500 to 1500 millivolts
- Reference solution options:Sealed
- Characteristics of the:Temperature Sensor (optional feature); Temperature Compensated; Measures pH
- Joint type:Double Junction
- Working temperature:14 to 212 F (-10 to 100 C)
- Electrode materials:Glass
- Appearance and installation options:In-Line
- Product category:Oxidation Reduction Potential (ORP) Electrodes
- The length of the:8.63 inch (219 mm)
- Diameter/width:0.7500 to 1 inch (19.05 to 25.4 mm)
-
HACH 12mm Combination Ph&ORP Sensor
Total of 5 Product Data
Click to View -
SWAN Analytical A-87.427.010
Total of 7 Product Data
Click to View- work pressure:0.0 to 29.01 psi (0.0 to 20.41 m H2O)
- ORP scope:-400 to 1200 millivolts
- Reference solution options:Sealed
- Characteristics of the:Measures pH
- Joint type:Single Junction
- Working temperature:32 to 122 F (0.0 to 50 C)
- Electrode materials:Epoxy or Polymer
- The electrode structure:Single Cell or No Reference
- Appearance and installation options:Plug PG 13,5 ;Other
- Diameter/width:0.4724 inch (12 mm)
- Product category:Oxidation Reduction Potential (ORP) Electrodes
- The length of the:5.94 inch (151 mm)
-
Endress+Hauser ( E+H ) Ceragel CPS 72 &72D
Total of 5 Product Data
Click to View- work pressure:0.0 to 145 psi (0.0 to 102 m H2O)
- ORP scope:-1500 to 1500 millivolts
- Reference solution options:Sealed
- Characteristics of the:Food or Sanitary; Submersible or Water Resistant
- Joint type:Double Junction
- Working temperature:5 to 275 F (-15 to 135 C)
- Electrode materials:Glass
- The electrode structure:Combination
- Appearance and installation options:In-Line
- Diameter/width:0.4700 inch (11.94 mm)
- Product category:Oxidation Reduction Potential (ORP) Electrodes
- The length of the:4.72 to 14.17 inch (120 to 360 mm)