Filter Criteria

Appearance And Installation Options

Electrode Structure

Electrode Material

Reference Plan Options

Ph Range

ph

Ph Accuracy

±% Full Scale

Response Time

Connector Type

Feature

Operating Temperature

Work Pressure

Filter Criteria

  • A-87.120.013
    • Electrode materials:Epoxy or Polymer
    • Appearance and installation options:Plug PG 13,6 ;Other
    • Product category:pH Electrodes
  • Ceragel CPS 71&71D
    • Scope of work pressure:0.0 to 189 psi (0.0 to 133 m H2O)
    • pH range:0.0 to 14 ph
    • Reference solution options:Sealed
    • Characteristics of the:Temperature Sensor; Temperature Compensated; Food / Sanitary; Submersible / Water Resistant
    • Joint type:Double Junction
    • Working temperature:32 to 275 F (0.0 to 135 C)
    • Electrode materials:Glass
    • The electrode structure:Combination
    • Appearance and installation options:In-Line
    • Diameter/width:0.4700 inch (11.94 mm)
    • The length of the:4.72 to 16.7 inch (120 to 424 mm)
    • Product category:pH Electrodes
  • KROHNE SMARTPAT Series

    Total of 1 Product Data

    Click to View
    SMARTPAT Series
    • Scope of work pressure:85 to 174 psi (59.82 to 122 m H2O)
    • pH range:0.0 to 14 ph
    • Characteristics of the:Temperature Sensor; Temperature Compensated
    • Joint type:Single Junction ; Double Junction
    • Working temperature:14 to 185 F (-10 to 85 C)
    • Electrode materials:Glass
    • The electrode structure:Combination
    • Appearance and installation options:In-Line
    • Diameter/width:0.4700 to 1.3 inch (11.94 to 33.02 mm)
    • The length of the:4.72 to 8.86 inch (120 to 225 mm)
    • Product category:pH Electrodes
  • Hamilton 238285

    Total of 75 Product Data

    Click to View
    238285
    • pH range:0.0 to 14 ph
    • Reference solution options:Refillable
    • Characteristics of the:Food or Sanitary
    • Working temperature:14 to 212 F (-10 to 100 C)
    • Electrode materials:Glass
    • The electrode structure:Combination
    • Appearance and installation options:Hand Held or Portable
    • Diameter/width:0.4724 inch (12 mm)
    • The length of the:4.72 inch (120 mm)
    • Product category:pH Electrodes
  • AdvantEDGE pH Electrode Sensor
    • Scope of work pressure:100 psi (70.38 m H2O)
    • pH range:0.0 to 14 ph
    • Response Time:30 seconds
    • Characteristics of the:Temperature Sensor
    • Joint type:Quad Junction
    • Working temperature:23 to 203 F (-5 to 95 C)
    • Electrode materials:Epoxy or Polymer
    • The electrode structure:Single Cell or No Reference
    • Appearance and installation options:In-Line
    • Product category:pH Electrodes
  • Combination pH probe
    • Product category:pH Electrodes
    • The reference element:Silver-Silver Chloride (Ag Ag/Cl)
    • pH range:0.0 to 14 ph
    • Response Time:5 to 15 seconds
    • Reference solution options:Refillable
    • Joint type:Double Junction
    • Working temperature:23 to 212 F (-5 to 100 C)
    • Electrode materials:Glass
    • The electrode structure:Combination
    • Appearance and installation options:Hand Held or Portable
    • Diameter/width:0.0492 to 0.2362 inch (1.25 to 6 mm)
    • The length of the:5.91 inch (150 mm)
  • Fermprobe® Type Replacement pH/Redox Electrodes
    • Scope of work pressure:150 psi (106 m H2O)
    • pH range:0.0 to 13 ph
    • Reference solution options:Sealed
    • Joint type:Double Junction
    • Working temperature:23 to 275 F (-5 to 135 C)
    • Product category:pH Electrodes
  • Industrial Grade pH Sensor
    • Scope of work pressure:200 psi (141 m H2O)
    • pH range:-0.5000 to 14.5 ph
    • Working temperature:5 to 302 F (-15 to 150 C)
    • Electrode materials:Epoxy or Polymer
    • Appearance and installation options:In-Line
    • Product category:pH Electrodes
  • pH Electrodes Suitable for Laboratory Use
    • pH range:0.0 to 14 ph
    • Working temperature:32 to 140 F (0.0 to 60 C)
    • Electrode materials:Epoxy or Polymer
    • Appearance and installation options:Hand Held or Portable
    • Product category:pH Electrodes
Filter Criteria

Filter Criteria

Appearance And Installation Options

Electrode Structure

Electrode Material

Reference Plan Options

Ph Range

ph

Ph Accuracy

±% Full Scale

Response Time

Connector Type

Feature

Operating Temperature

Work Pressure

}