  • Model TS
    • Switch type:Electro-Mechanical Switch
    • Toss a few:Double Throw
    • The number of:Double Pole
    • work pressure:0.0 to 500 psi (0.0 to 352 m H2O)
    • Velocity range:0.0 to 150 ft/sec (0.0 to 45.72 m/sec)
    • Measurement technology:Thermal
    • Medium temperature:-50 to 350 F (-46 to 177 C)
    • Measuring the dielectric:Liquid
    • Characteristics of the:Sanitary ; Suspended Solids / Slurries
    • Working temperature:-50 to 140 F (-46 to 60 C)
    • The terminal fittings:Clamp
    • Pipe diameter:1.00 to 2.00 inch (25.4 to 50.8 mm)
    • The installation:Insertion
    • Additional variable measurement:Temperature; Level
    • Product category:Velocity Flow Switches
    • current:8 amps
    • Ac voltage:250 volts
    • Audit certification:Canadian Standards Association; European Committee for Electrotechnical Standardization; FM
  • FST1000
    • Switch type:Electro-Mechanical Switch
    • Toss a few:Single Throw
    • The number of:Single Pole
    • Velocity range:0.0 to 167 ft/sec (0.0 to 50.8 m/sec)
    • Measuring the dielectric:Gas
    • Working temperature:-40 to 250 F (-40 to 121 C)
    • The installation:Insertion
    • precision:2 ±%
    • Audit certification:CE
    • current:10 amps
    • Direct current voltage:15 to 24 volts
    • Product category:Velocity Flow Switches
  • Model TS
    • Switch type:Electro-Mechanical Switch
    • Toss a few:Double Throw
    • The number of:Double Pole
    • work pressure:0.0 to 500 psi (0.0 to 352 m H2O)
    • Velocity range:0.0 to 150 ft/sec (0.0 to 45.72 m/sec)
    • Measurement technology:Thermal
    • Medium temperature:-50 to 350 F (-46 to 177 C)
    • Measuring the dielectric:Liquid
    • Characteristics of the:Sanitary ; Suspended Solids / Slurries
    • Working temperature:-50 to 140 F (-46 to 60 C)
    • The terminal fittings:Clamp
    • Pipe diameter:1.00 to 2.00 inch (25.4 to 50.8 mm)
    • The installation:Insertion
    • Additional variable measurement:Temperature; Level
    • Product category:Velocity Flow Switches
    • current:8 amps
    • Ac voltage:250 volts
    • Audit certification:Canadian Standards Association; European Committee for Electrotechnical Standardization; FM
  • Sitron CF12

    Total of 2 Product Data

    Click to View
    CF12
    • Switch type:Electro-Mechanical Switch
    • Toss a few:Double Throw
    • The number of:Single Pole
    • work pressure:1450 psi (1021 m H2O)
    • Velocity range:0.0984 to 16.4 ft/sec (0.0300 to 5 m/sec)
    • Measuring the dielectric:Liquid; Gas
    • Working temperature:14 to 176 F (-10 to 80 C)
    • The terminal fittings:Flanged; Threaded
    • Pipe diameter:0.50 to 2.00 inch (12.7 to 50.8 mm)
    • The installation:Insertion
    • Product category:Velocity Flow Switches
    • precision:10 ±%
    • Ac voltage:250 volts
    • current:5 amps
  • DF-KL - Digital Flowmeter
    • work pressure:85 to 1450 psi (59.82 to 1020 m H2O)
    • Measurement technology:Paddlewheel
    • Medium temperature:-10 to 180 F (-23 to 82 C)
    • Measuring the dielectric:Liquid
    • The electrical output:Analog Current;Analog Voltage
    • Working temperature:-10 to 180 F (-23 to 82 C)
    • The terminal fittings:Threaded
    • Product category:Velocity Flow Switches
  • InnovaSwitch™ Level Switch
    • Toss a few:Double Throw
    • The number of:Double Pole
    • work pressure:3000 psi (2111 m H2O)
    • Velocity range:0.0100 to 500 ft/sec (0.0030 to 152 m/sec)
    • Measurement technology:Thermal
    • Medium temperature:-100 to 850 F (-73 to 454 C)
    • Measuring the dielectric:Liquid; Gas
    • Characteristics of the:Built-in Alarm Indicator ;Other
    • The electrical output:Analog Current;Analog Voltage
    • Working temperature:-40 to 140 F (-40 to 60 C)
    • The terminal fittings:Threaded
    • The installation:Insertion
    • Additional variable measurement:Level
    • Ac voltage:115 to 230 volts
    • Audit certification:Canadian Standards Association; European Committee for Electrotechnical Standardization; CE, ISO 9001
    • Product standards:RoHS; WEEE Compliant
    • Product category:Velocity Flow Switches
    • Direct current voltage:24 volts
  • Model 100CS
    • Velocity range:0.0833 to 417 ft/sec (0.0254 to 127 m/sec)
    • Measurement technology:Thermal
    • Medium temperature:0 to 212 F (-18 to 100 C)
    • Measuring the dielectric:Liquid; Gas
    • Characteristics of the:Sanitary
    • Working temperature:0 to 120 F (-18 to 49 C)
    • The terminal fittings:Flanged ; Threaded; Sanitary
    • Pipe diameter:1.00 to ? inch (25.4 to ? mm)
    • The installation:Insertion
    • According to:Digital
    • Product category:Velocity Flow Switches
    • precision:1 ±%
  • GF Signet 2537 Rotor-X Paddlewheel Flowmeter
    • work pressure:180 to 200 psi (127 to 141 m H2O)
    • Velocity range:0.3000 to 20 ft/sec (0.0914 to 6.1 m/sec)
    • Measurement technology:Paddlewheel
    • Measuring the dielectric:Liquid
    • The electrical output:Analog Current
    • The interface options:Serial / Digital
    • Pipe diameter:0.50 to 8.00 inch (12.7 to 203 mm)
    • Product category:Velocity Flow Switches
  • FlexSwitch® FLT93C
    • Switch type:Electro-Mechanical Switch
    • Toss a few:Double Throw
    • The number of:Single Pole; Double Pole
    • work pressure:0.0 to 1500 psi (0.0 to 1056 m H2O)
    • Velocity range:0.0100 to 120 ft/sec (0.0030 to 36.58 m/sec)
    • Measurement technology:Thermal
    • Medium temperature:-100 to 500 F (-73 to 260 C)
    • Measuring the dielectric:Liquid; Gas
    • Characteristics of the:Sanitary
    • Working temperature:-40 to 140 F (-40 to 60 C)
    • The terminal fittings:Flanged
    • The installation:Insertion
    • Switch to normal:Normally Open; Normally Closed
    • Additional variable measurement:Temperature; Level
    • precision:2 ±%
    • current:6 amps
    • Ac voltage:115 volts
    • Product category:Velocity Flow Switches
    • Direct current voltage:24 volts
    • Audit certification:ATEX; Canadian Standards Association; European Committee for Electrotechnical Standardization; FCI, NFPA Code 30 Compliance
  • 1000 EL Series
    • work pressure:580 psi (408 m H2O)
    • Velocity range:1.64 to 32.81 ft/sec (0.5000 to 10 m/sec)
    • Measurement technology:Electromagnetic; Sonar; Turbine; Ultrasonic; Vortex (Shedding) Meter
    • Medium temperature:-40 to 356 F (-40 to 180 C)
    • Measuring the dielectric:Liquid
    • Characteristics of the:Suspended Solids / Slurries ;Other
    • The electrical output:Current; Frequency; Voltage
    • The interface options:Serial / Digital
    • The terminal fittings:Flanged
    • Pipe diameter:0.98 to 11.81 inch (25 to 300 mm)
    • The installation:In-line
    • Product standards:RoHS; WEEE Compliant
    • Product category:Velocity Flow Switches
    • precision:0.2000 ±%
    • Audit certification:ATEX (optional feature)
Filter Criteria