  • FSW530
    • precision:1 ±%
    • work pressure:100 to 500 psi (70.38 to 352 m H2O)
    • Measurement technology:Turbine ;Other
    • Medium temperature:131 F (55 C)
    • Measuring the dielectric:Liquid
    • Characteristics of the:Built-in Alarm Indicator
    • Working temperature:41 to 131 F (5 to 55 C)
    • The terminal fittings:Threaded
    • Pipe diameter:0.12 to 0.38 inch (3.17 to 9.52 mm)
    • The installation:In-line
    • The instrument type:Volumetric Flow Meter
    • Product category:Volumetric Liquid Flow Switches
    • The liquid volume flow:0.01 to 2.64 GPM (0.0200 to 10 L/min)
  • 1800-42570
    • Switch type:Electro-Mechanical Switch
    • Toss a few:Double Throw
    • The number of:Single Pole
    • work pressure:150 psi (106 m H2O)
    • Measuring the dielectric:Liquid
    • Working temperature:-20 to 300 F (-29 to 149 C)
    • The terminal fittings:Socket Weld / Union
    • Pipe diameter:1.00 inch (25.4 mm)
    • The installation:In-line
    • The liquid volume flow:0.50 GPM (1.89 L/min)
    • The instrument type:Volumetric Flow Meter
    • Product category:Volumetric Liquid Flow Switches
  • Sitron CF12

    Total of 1 Product Data

    Click to View
    CF12
    • Switch type:Electro-Mechanical Switch
    • Toss a few:Double Throw
    • The number of:Single Pole
    • work pressure:1450 psi (1021 m H2O)
    • Measuring the dielectric:Liquid; Gas
    • Working temperature:14 to 176 F (-10 to 80 C)
    • The terminal fittings:Threaded
    • Pipe diameter:0.25 to 0.50 inch (6.35 to 12.7 mm)
    • The installation:In-line
    • The instrument type:Volumetric Flow Meter
    • The liquid volume flow:0.00 to 0.08 GPM (0.0030 to 0.3000 L/min)
    • Product category:Volumetric Liquid Flow Switches
    • current:5 amps
    • Ac voltage:250 volts
  • INTEK, Inc. Model 100

    Total of 3 Product Data

    Click to View
    Model 100
    • precision:1 ±%
    • work pressure:500 psi (352 m H2O)
    • Measurement technology:Thermal
    • Medium temperature:0 to 140 F (-18 to 60 C)
    • Measuring the dielectric:Liquid
    • Characteristics of the:Sanitary Applications Rated (optional feature); Suspended Solids / Slurries
    • The electrical output:Analog Current;Analog Voltage
    • Working temperature:0 to 140 F (-18 to 60 C)
    • The terminal fittings:Flanged ; Threaded; Tube End/Hose Nipple; Sanitary
    • Pipe diameter:0.06 to 1.00 inch (1.59 to 25.4 mm)
    • The installation:In-line
    • Product category:Volumetric Liquid Flow Switches
    • The liquid volume flow:0.00 to 20.00 GPM (7.58E-8 to 75.76 L/min)
    • According to:Digital
    • The instrument type:Volumetric Flow Meter
  • FS10A
    • precision:0.5000 ±%
    • Switch type:Solid-State Switch
    • work pressure:0.0 to 600 psi (0.0 to 422 m H2O)
    • Measurement technology:Thermal
    • Medium temperature:-40 to 500 F (-40 to 260 C)
    • Measuring the dielectric:Liquid; Gas
    • Characteristics of the:Built-in Alarm Indicator
    • The electrical output:Analog Current
    • Working temperature:-40 to 160 F (-40 to 71 C)
    • The terminal fittings:Flanged; Threaded
    • Pipe diameter:0.25 to 0.50 inch (6.35 to 12.7 mm)
    • The installation:Insertion
    • Switch to normal:Normally Open
    • Product category:Volumetric Liquid Flow Switches
    • The instrument type:Volumetric Flow Meter
    • Audit certification:ATEX; FM, FMc, IECEx, CE Mark, CRN, ANSI / ISA 12.27.01-2011, SIL
    • The liquid volume flow:0.00 to 0.03 GPM (0.0038 to 0.1136 L/min)
    • Additional variable measurement:Temperature
    • Direct current voltage:24 volts
  • FS-550 Series
    • Switch type:Electro-Mechanical Switch
    • Toss a few:Double Throw
    • The number of:Single Pole
    • work pressure:2000 psi (1408 m H2O)
    • Medium temperature:-30 to 300 F (-34 to 149 C)
    • Measuring the dielectric:Liquid
    • Working temperature:-30 to 300 F (-34 to 149 C)
    • The terminal fittings:Threaded
    • Pipe diameter:0.50 to 1.00 inch (12.7 to 25.4 mm)
    • The installation:Insertion
    • Switch to normal:Normally Open
    • Audit certification:Underwriters Laboratory; Canadian Standards Association; CE, FM
    • Product category:Volumetric Liquid Flow Switches
    • Product standards:RoHS
    • The instrument type:Volumetric Flow Meter
    • The liquid volume flow:5.00 to 52.00 GPM (18.94 to 197 L/min)
  • 200005500
    • Switch type:Electro-Mechanical Switch
    • work pressure:3600 psi (2534 m H2O)
    • Medium temperature:176 F (80 C)
    • Measuring the dielectric:Liquid
    • The terminal fittings:Threaded
    • Pipe diameter:0.38 inch (9.52 mm)
    • The installation:In-line
    • The instrument type:Volumetric Flow Meter
    • The liquid volume flow:1.00 to 8.00 GPM (3.79 to 30.3 L/min)
    • Ac voltage:400 volts
    • current:3 amps
    • Product category:Volumetric Liquid Flow Switches
  • Volker Automation FXW

    Total of 3 Product Data

    Click to View
    FXW

    Volker Automation FXW Liquid Flow Switch

  • Liquid level detection LS 0155

    Lingtu Sensing Liquid Level Detection LS 0155 Liquid Flow Switch

Filter Criteria

Filter Criteria

Switch Type

Measurement Technology

Switch Normal State

Number Of Poles

Measuring Medium

Medium Temperature

Accuracy

±%

Operating Temperature

Work Pressure

Electrical Output

Interface Options

Pipe Diameter

Installation Type

End Fittings

Feature

}