Filter Criteria
Flue Gas Analyzer/combustion Analyzer
-
RS Components 146777
Total of 2 Product Data
Click to View -
ABB Measurement & Analytics AK100 Series
Total of 3 Product Data
Click to View- Monitoring gas quantity:Multi
- Measurement technology:Thermal Conductivity Cell
- Response Time:40 seconds
- The channel number:2
- Characteristics of the:Audible or Visual Alarms; Hazardous Environment; Intrinsically Safe
- The electrical output:Current; Switch or Relay
- According to:Digital
- Working temperature:32 to 113 F (0 to 45 C)
- Working humidity:90 %
- Product form:Fixed
- Measuring type:%Volume
- Type of gas:H2
- application:Ambient Air Monitoring; Process Gas
- Product category:Combustion Analyzers
-
Waldom Electronics ACF5000
Total of 4 Product Data
Click to View- Monitoring gas quantity:Multi
- Response Time:400 seconds
- According to:Digital
- Working temperature:41 to 86 F (5 to 30 C)
- Working humidity:0 to 95 %
- Product form:Fixed
- Measuring type:%Volume; Trace
- Type of gas:Hydrocarbons (CH4 0-10ppm to 0-280ppm, CH2O 0-15ppm); HCl (0-15ppm, 0-125ppm); HF (0-3ppm, 0-7ppm); Methane (CH4) / Natural Gas (0-10ppm, 0-280ppm); NO (0-110ppm, 0-1500ppm); NO2 (0-40ppm, 0-300ppm); NxOx (N20 0-25ppm, 0-500ppm); O2 (0-25% by volume); SO2 (0-25ppm, 0-525ppm); Water Vapor (0-40% by volume) (VOC); NH3 (0-7ppm, 0-300ppm); CO2 (0-30% by volume); CO (0-65ppm, 0-3200ppm)
- application:Continuous Emissions Monitoring; Process Gas
- Product category:Combustion Analyzers
-
Inspector Tools T4005633271
Total of 29 Product Data
Click to View -
Sensidyne 7015406
Total of 1 Product Data
Click to View- Monitoring gas quantity:Single
- The channel number:1 #
- Characteristics of the:Intrinsically Safe
- According to:Analog
- Product form:Portable
- Measuring type:%Volume (optional feature); Trace (optional feature)
- Type of gas:Hydrocarbons (optional feature) (0.3-5 mg/M3); O2 (optional feature) (2-24%Volume); Water Vapor (optional feature) (20-160 mg/M3); CO2 (optional feature) (100-3000ppm); CO (optional feature) (5-100ppm)
- application:Personal Exposure Monitoring; Confined Space Entry; Continuous Emissions Monitoring; Ambient Air Monitoring; Process Gas
- Product category:Combustion Analyzers
-
Eagle Eye Power Solutions, LLC HGD-2000
Total of 1 Product Data
Click to View- Monitoring gas quantity:Single; Multi
- Characteristics of the:Audible or Visual Alarms; Controller
- The electrical output:Switch
- According to:Digital
- Working temperature:14 to 104 F (-10 to 40 C)
- Product form:Fixed
- Measuring type:%LEL;%LFL
- Type of gas:H2; Hg; Methane (CH4) / Natural Gas; O2
- application:Confined Space Entry; Ambient Air Monitoring
- Product category:Combustion Analyzers
-
Panametrics XMTC
Total of 1 Product Data
Click to View- Monitoring gas quantity:Multi
- Measurement technology:Thermal Conductivity;Other
- Response Time:20 seconds
- Characteristics of the:Hazardous Environments
- The electrical output:Current
- Working temperature:158 F (70 C)
- Product form:Fixed
- Measuring type:%Volume
- Type of gas:Hydrocarbons; H2; CO2
- application:Process Gas
- Product category:Combustion Analyzers
-
AMETEK Land Lancom 4
Total of 1 Product Data
Click to View- Monitoring gas quantity:Multi
- Measurement technology:Catalytic; Electrochemical; Infrared
- The channel number:12
- Characteristics of the:Data Logger; Self Calibration
- The electrical output:Current
- According to:Digital
- Working temperature:23 to 113 F (-5 to 45 C)
- Product form:Handheld; Portable
- Measuring type:%Volume; Trace
- Type of gas:Hydrocarbons (0 - 4%); H2S (0- 1,000 ppm); NO (0-1,000 to 0-5,000 ppm); NO2 (0-100 ppm, 0-1,000 ppm); O2 (0 - 305); SO2 (0-2,000 ppm to 0-5,000 ppm); CO2 (0 - 25%); CO (0-10,000 ppm, 0 - 10%)
- application:Continuous Emissions Monitoring
- Product category:Combustion Analyzers
-
RKI Instruments, Inc. FI-800
Total of 1 Product Data
Click to View- Monitoring gas quantity:Multi
- Measurement technology:Optical Interferometric ;Other
- Characteristics of the:Audible or Visual Alarms; Hazardous Environment
- The electrical output:Current
- According to:Digital
- Working temperature:-40 to 104 F (-40 to 40 C)
- Product form:Fixed
- Measuring type:%LEL or %LFL; %Volume
- Type of gas:H2
- application:Process Gas
- Product category:Combustion Analyzers
-
Det-Tronics EQ3XXX
Total of 1 Product Data
Click to View