Filter Criteria

Instrument Type

Appearance And Installation Type

Measurement Type

Gas Classification

Gas Type

Number Of Channels

#

Response Time

Electrical Output

Show

Operating Temperature

Working Humidity

%

Feature

Application

Filter Criteria

  • Sensirion 1-101646-01

    Total of 1 Product Data

    Click to View
    1-101646-01
    • The instrument type:Detector
    • Product model:1-101646-01
    • Product category:Gas Instruments
    • manufacturers:Sensirion
  • RS Components 1461309

    Total of 4 Product Data

    Click to View
    1461309
    • Characteristics of the:Audible or Visual Alarms
    • Type of gas:CO
    • The instrument type:Detector
    • Product category:Gas Instruments
  • GAA630-M
    • According to:Digital
    • Working temperature:41 to 131 F (5 to 55 C)
    • Installation type:Fixed
    • Measuring type:%Volume; Trace
    • Type of gas:CO2 (0-20% by volume); NO (0-1000 ppm); NO2 (0-400 ppm); NxOx (0-1400 ppm); O2 (0-25% by volume); SO2 (0-500 ppm)
    • The instrument type:Monitor; Analyzer
    • application:Continuous Emissions Monitoring
    • Number of Gases Monitored:Multi
    • Sensitivity technology:Infrared; Non-Dispersive Infrared
    • Product category:Gas Instruments
    • Response Time:3 seconds
    • Characteristics of the:Interchangeable Probes
    • The electrical output:Current
  • PCE-AC 2000
    • Characteristics of the:Temperature Measurement
    • According to:Digital
    • Working temperature:32 to 122 F (0 to 50 C)
    • Installation type:Fixed
    • Measuring type:Trace
    • Type of gas:CO2
    • The instrument type:Analyzer
    • Monitoring gas quantity:Single
    • Product category:Gas Instruments
  • E+E Elektronik EE85

    Total of 2 Product Data

    Click to View
    EE85
    • Response Time:195 seconds
    • Characteristics of the:Self Calibration
    • The electrical output:Voltage; Current; Switch or Relay
    • Working temperature:-4 to 140 F (-20 to 60 C)
    • Working humidity:0 to 95 %
    • Installation type:Fixed
    • Measuring type:Trace
    • Type of gas:CO2
    • The instrument type:Detector
    • application:Ambient Air Monitoring
    • Monitoring gas quantity:Single
    • Product category:Gas Instruments
    • Sensitivity technology:Infrared
  • Oxymaster 16TDP
    • Response Time:45 seconds
    • The channel number:1
    • Characteristics of the:Audible or Visual Alarms; Interchangeable Probes; Temperature
    • The electrical output:Current
    • According to:Digital
    • Working temperature:32 to 122 F (0 to 50 C)
    • Installation type:Fixed
    • Measuring type:Trace
    • Type of gas:O2 (0-10000 ppm O2); Water Vapor
    • The instrument type:Monitor; Analyzer
    • application:Process Gas
    • Sensitivity technology:Electrochemical; Micro-Fuel Cell
    • Product category:Gas Instruments
    • Monitoring gas quantity:Multi
    • Appearance of the form:Analyzer
    • Operating Temp:32 to 122 F (0 to 50 C)
    • Digital output:Serial Interface (optional feature)
    • Measured variables:Absolute Humidity; Temperature; Oxygen Concentration
  • Extractive Gas Analyzers
    • Installation type:Fixed
    • Type of gas:O2
    • The instrument type:Analyzer
    • application:Continuous Emissions Monitoring; Process Gas
    • Product category:Gas Instruments
  • EC-Gold Dual
    • The electrical output:Current
    • According to:Digital
    • Working temperature:-4 to 104 F (-20 to 40 C)
    • Installation type:Fixed
    • Measuring type:%Volume; Trace
    • Type of gas:Toxic; CO (0-500ppm); Cl2 (0-10ppm); H2S (0-100ppm); NO2 (0-20ppm); O2 (0-30%)
    • The instrument type:Detector; Monitor
    • application:Ambient Air Monitoring
    • Product category:Gas Instruments
    • Number of Gases Monitored:Multi
    • Characteristics of the:Audible or Visual Alarms; Controller
  • Cel-4 Control Panels
    • The channel number:4
    • Characteristics of the:Controller; Hazardous Environment
    • The electrical output:Analog Current;Switch
    • According to:Digital
    • Working humidity:5 to 95 %
    • Installation type:Fixed
    • Measuring type:Trace
    • Type of gas:Toxic; Combustible; CO2 (optional feature); CO (optional feature); Cl2 (optional feature); Hydrocarbons (optional feature); H2 (optional feature); H2S (optional feature); Methane (CH4) / Natural Gas (optional feature); NO2 (optional feature); O2 (optional feature); SO2 (optional feature)
    • The instrument type:Detector
    • application:Ambient Air Monitoring
    • Monitoring gas quantity:Multi
    • Product category:Gas Instruments
    • Sensitivity technology:Catalytic (optional feature); Electrochemical (optional feature); Infrared (optional feature)
  • SIPROCESS UV600
    • The channel number:4
    • According to:Digital
    • Working temperature:41 to 113 F (5 to 45 C)
    • Installation type:Fixed
    • Measuring type:Trace
    • Type of gas:Toxic; H2S (0 to 1000 ppm); NO (0 to 1000 ppm); NO2 (0 to 1000 ppm); SO2 (0 to 1000 ppm)
    • The instrument type:Analyzer
    • application:Continuous Emissions Monitoring
    • Sensitivity technology:PID
    • Product category:Gas Instruments
    • Number of Gases Monitored:Multi
Filter Criteria

Filter Criteria

Instrument Type

Appearance And Installation Type

Measurement Type

Gas Classification

Gas Type

Number Of Channels

#

Response Time

Electrical Output

Show

Operating Temperature

Working Humidity

%

Feature

Application

}