Filter Criteria

Measurement Technology

Measured Variables

Relative Humidity Range

Relative Humidity Accuracy

Dew Point Range

Dew Point Accuracy

Temperature Measurement Range

Temperature Measurement Accuracy

Compensate

Operating Temperature

Display Method

Digital Output

Electrical Output

Feature

Filter Criteria

  • Model SEM161
    • Accuracy of relative humidity:2 %
    • Relative humidity range:0.0 to 100 %
    • Measured variables:Relative Humidity; Temperature
    • The electrical output:Current
    • Working temperature:-22 to 185 F (-30 to 85 C)
    • Product category:Humidity Transmitters
  • HVAC Explosionproof Electric Sensors and Switches, ExCos/ExBin Range
    • Relative humidity range:0.0 to 95 %
    • Measured variables:Relative Humidity; Pressure; Temperature
    • According to:Digital Readouts
    • Working temperature:-4 to 122 F (-20 to 50 C)
    • Product category:Humidity Transmitters
    • Scope of work pressure:1.09 psi (0.7656 m H2O)
    • Measuring the dielectric:Gas
    • The product type:Sensor
    • Measuring type:Gauge
  • AH711P3L120T1HT480N1N25NT
    • Relative humidity range:0.0 to 100 %
    • Measured variables:Relative Humidity
    • The electrical output:Current
    • Product category:Humidity Transmitters
  • Kahn Easidew

    Total of 6 Product Data

    Click to View
    Easidew
    • Precision dew point:3.60 +/-F (2.00 +/-C)
    • Dew point range:-148 to 68 F (-100 to 20 C)
    • Measured variables:Moisture Content; DewPoint
    • Measurement technology:Capacitive; Ceramic Substrate
    • The compensation:Temperature Compensated
    • Characteristics of the:Self Testing or Diagnostics
    • The electrical output:Current
    • Working temperature:-40 to 140 F (-40 to 60 C)
    • Product category:Humidity Transmitters
  • TEGAM HTRH

    Total of 3 Product Data

    Click to View
    HTRH
    • Accuracy of relative humidity:2 %
    • Relative humidity range:3 to 95 %
    • Measured variables:Relative Humidity; Temperature
    • The electrical output:Current
    • Working temperature:-40 to 356 F (-40 to 180 C)
    • Product category:Humidity Transmitters
    • application:Moisture / Water Content in Gases / Air
    • Appearance of the form:Sensor; Transmitter
    • Operating Temp:-40 to 356 F (-40 to 180 C)
  • Vaisala PTU300

    Total of 18 Product Data

    Click to View
    PTU300
    • Accuracy of relative humidity:1 %
    • Relative humidity range:0.0 to 100 %
    • Measured variables:Relative Humidity; Pressure; Temperature
    • Measurement technology:Capacitive; Vaisala HUMICAP® 180R. 180C, or 180
    • Digital output:Serial Interface
    • Characteristics of the:Datalogger
    • The electrical output:Current; Voltage
    • Working temperature:-40 to 140 F (-40 to 60 C)
    • Product category:Humidity Transmitters
  • CARLO GAVAZZI ESTHD50x

    Total of 21 Product Data

    Click to View
    ESTHD50x
    • Accuracy of relative humidity:3 %
    • Relative humidity range:0.0 to 100 %
    • Measured variables:Relative Humidity; Temperature
    • Measurement technology:Capacitive
    • The electrical output:Current; Voltage
    • Working temperature:32 to 122 F (0 to 50 C)
    • Product category:Humidity Transmitters
  • E+E Elektronik EE150

    Total of 14 Product Data

    Click to View
    EE150
    • Accuracy of relative humidity:3 to 5 %
    • Relative humidity range:10 to 90 %
    • Measured variables:Relative Humidity; Temperature
    • Measurement technology:Capacitive
    • The electrical output:Current; Voltage
    • Working temperature:23 to 131 F (-5 to 55 C)
    • Product category:Humidity Transmitters
  • DewTrak II
    • Measured variables:Relative Humidity; DewPoint
    • Measurement technology:Chilled Mirror
    • Digital output:Serial Interface
    • The electrical output:Current; Voltage
    • According to:Digital Readouts
    • Product category:Humidity Transmitters
Filter Criteria

Filter Criteria

Measurement Technology

Measured Variables

Relative Humidity Range

Relative Humidity Accuracy

Dew Point Range

Dew Point Accuracy

Temperature Measurement Range

Temperature Measurement Accuracy

Compensate

Operating Temperature

Display Method

Digital Output

Electrical Output

Feature

}