Filter Criteria

Product Type

Measurement Technology

Measurement Mode

Inclination Range

Accuracy

Output

Supply Voltage

Operating Temperature

Filter Criteria

  • Accustar® Electronic Clinometer
    • Angle range:-60 to 60 degrees
    • Number of shaft:Single Axis
    • The output:Analog (optional feature); Digital (optional feature)
    • The power supply voltage:-12 to 12 volts
    • Working temperature:-22 to 149 F (-30 to 65 C)
    • The product type:Module,
    • Product category:Tilt Sensors
    • Trigger:Tilt Sensor
  • Model 800P
    • Angle range:-5 to 5 degrees
    • Number of shaft:2
    • The power supply voltage:9 volts
    • Working temperature:-13 to 158 F (-25 to 70 C)
    • The product type:Module,
    • Product category:Tilt Sensors
    • Trigger:Tilt Sensor
  • Rieker 2160-F

    Total of 1 Product Data

    Click to View
    2160-F
    • Angle range:-60 to 60 degrees
    • Number of shaft:Single Axis
    • The output:Analog
    • Working temperature:-49 to 180 F (-45 to 82 C)
    • The product type:Independent product
    • Product category:Tilt Sensors
    • Trigger:Tilt Sensor
  • SSY0090C
    • precision:2 degrees
    • Angle range:-45 to 45 degrees
    • Number of shaft:biaxial
    • The output:Analog
    • The power supply voltage:5 volts
    • Working temperature:-4 to 158 F (-20 to 70 C)
    • The product type:Module,
    • Measurement technology:Electrolytic
    • Product category:Tilt Sensors
    • Trigger:Tilt Sensor
  • 0729-1736-99
    • precision:0.2000 degrees
    • Angle range:1 to 35 degrees
    • Number of shaft:biaxial
    • The output:Analog
    • The power supply voltage:7 to 30 volts
    • Working temperature:-31 to 158 F (-35 to 70 C)
    • The product type:Module,
    • Measurement technology:Electrolytic
    • Product category:Tilt Sensors
    • Trigger:Tilt Sensor; Tilt Switch
  • Nanjing Welpu TS-91V1

    Total of 8 Product Data

    Click to View
    TS-91V1
    • Number of shaft:Single shaft
    • Working temperature:- 30 to + 125 ° C
    • The product type:Sensor/transducer
    • Measurement technology:MEMS;
    • Angle range:Plus or minus 15 ° to + 90 °
    • The sensitivity:2000 mV/g
    • The noise density:<0.001 °/√Hz
    • Resolution:0.001°
    • Bandwidth (±5%):0 to 250 Hz
    • The amplitude of nonlinear:< 0.25 (maximum) % FSO
    • The power supply voltage:6 to 40 V
    • The temperature coefficient of the scaling factor:PPM/K + 200 (maximum)
    • The temperature coefficient of deviation (maximum):+ / - 0.05 ° / K (maximum)
    • Long-term stability of the scaling factor:500 (typical) | 1000 parts per million (maximum)
    • Offset stability for a long time:0.2 ° (typical) | 0.5 ° (maximum)
    • Impact limit:2000 g
    • The shell material:aluminum
    • Protection level:IP67
    • The weight of the:78 g