Thermocouple Temperature Transmitter

  • iTEMP® HART® DIN rail TMT122
    • Measuring temperature range:-454 to 4523 F (-270 to 2495 C)
    • The output:Analog Current
    • Other input:Accepts Generic Analog Voltage Inputs; Accepts Generic Resistance Inputs
    • Sensor connection:Screw Clamps or Lugs
    • User Interface:Computer Interface
    • Working temperature:-40 to 185 F (-40 to 85 C)
    • installation:DIN Rail Mounting
    • Thermocouple in the form of:E; J; K; N; T; B; S; R
    • Product category:Thermocouple Temperature Transmitters
    • The power supply voltage:12 To 35 V
  • TF 202&TF 202-Ex
    • Measuring temperature range:-454 to 4200 F (-270 to 2316 C)
    • Other input:Accepts Generic Analog Voltage Inputs; Accepts Generic Analog Current Inputs; Accepts Generic Resistance Inputs
    • Sensor connection:Screw Clamps or Lugs
    • User Interface:Computer Interface
    • Working temperature:-40 to 185 F (-40 to 85 C)
    • installation:Board or Cabinet Mounting
    • Thermocouple in the form of:E; J; K; N; T; B; S; R
    • Product category:Thermocouple Temperature Transmitters
    • Characteristics of the:Intrinsically Safe
    • The power supply voltage:9-32 VDC
  • TF 02&TF 02-Ex
    • Measuring temperature range:-454 to 4200 F (-270 to 2316 C)
    • Other input:Accepts Generic Analog Voltage Inputs; Accepts Generic Analog Current Inputs; Accepts Generic Resistance Inputs
    • Sensor connection:Screw Clamps or Lugs
    • User Interface:Computer Interface
    • Working temperature:-40 to 185 F (-40 to 85 C)
    • installation:Board or Cabinet Mounting
    • Thermocouple in the form of:E; J; K; N; T; B; S; R
    • Product category:Thermocouple Temperature Transmitters
    • The power supply voltage:9-32VDC
    • Characteristics of the:Intrinsically Safe
  • KS 816
    • Measuring temperature range:-328 to 4172 F (-200 to 2300 C)
    • Other input:Accepts Generic Analog Voltage Inputs; Accepts Generic Analog Current Inputs; Accepts Generic Resistance Inputs
    • User Interface:Computer Interface
    • Output interface:Serial Interface
    • Working temperature:32 to 140 F (0.0 to 60 C)
    • installation:DIN Rail Mounting
    • Thermocouple in the form of:E; J; K; N; T; S; R; W
    • Product category:Thermocouple Temperature Transmitters
  • TF 02&TF 02-Ex
    • Measuring temperature range:-454 to 4200 F (-270 to 2316 C)
    • Other input:Accepts Generic Analog Voltage Inputs; Accepts Generic Analog Current Inputs; Accepts Generic Resistance Inputs
    • Sensor connection:Screw Clamps or Lugs
    • User Interface:Computer Interface
    • Working temperature:-40 to 185 F (-40 to 85 C)
    • installation:Board or Cabinet Mounting
    • Thermocouple in the form of:E; J; K; N; T; B; S; R
    • Product category:Thermocouple Temperature Transmitters
    • The power supply voltage:9-32VDC
    • Characteristics of the:Intrinsically Safe