Filter Criteria

Appearance

Number Of Electrodes (Input)

#

ISE Scope

Accuracy

Control Relay Quantity

#

Electrical Output

Interface Options

Display Type

User Control

Medium Temperature

Operating Temperature

Filter Criteria

Ion Selective Electrode Measuring Instrument (ise Meter)

  • 8037
    • precision:1.00E-5 ppm
    • Number of electrodes:1
    • ISE scope:0 to 10 ppm
    • Medium temperature:41 to 131 F (5 to 55 C)
    • The electrical output:Analog Current; Switch / Alarm Relay
    • The interface options:Serial
    • User control:Digital Front Panel
    • Working temperature:32 to 131 F (0 to 55 C)
    • Appearance of the form:Modular; Panel (optional feature); Wall Mount
    • Features and functions:Built-in or Self Calibration; Extreme Environment
    • Instrument features:Automatic Temperature Compensation
    • Other output:Modbus
    • Product category:Ion Specific Electrode Meters
    • The water quality parameters:ISE Meter
  • PHI-359
    • precision:0.0200 ±pH
    • Number of electrodes:1
    • ISE scope:0 to 1990 ppm
    • The electrical output:Analog Voltage
    • The interface options:Serial
    • Display type:Digital Display
    • User control:Digital Front Panel
    • Appearance of the form:Portable; Lab / Benchtop
    • Features and functions:Battery Powered; Built-in or Self Calibration
    • The water quality parameters:ISE Meter; pH
    • pH range:0.0 to 14 pH
    • PH measurement features:Temperature Measurement
    • Instrument features:Automatic Temperature Compensation
    • Product category:Ion Specific Electrode Meters
  • Mettler-Toledo S50

    Total of 6 Product Data

    Click to View
    S50
    • precision:0.0020 ±pH
    • Medium temperature:-22 to 266 F (-30 to 130 C)
    • The number control relay:0.0
    • The interface options:Serial
    • Display type:Digital Display
    • User control:Digital Front Panel
    • Appearance of the form:Portable
    • Features and functions:Battery Powered
    • memory:GLP Memory Storage
    • Product category:Ion Specific Electrode Meters
    • The water quality parameters:ISE Meter; pH
    • PH measurement features:Temperature Measurement
    • pH range:-2 to 20 pH
  • 7835
    • precision:0.0020 ppm
    • Number of electrodes:1
    • ISE scope:0 to 1 ppm
    • The electrical output:Analog Current; Switch / Alarm Relay
    • User control:Digital Front Panel
    • Working temperature:32 to 131 F (0 to 55 C)
    • Appearance of the form:Modular
    • The water quality parameters:ISE Meter
    • Features and functions:Self-test / Diagnostics
    • Instrument features:Automatic Temperature Compensation
    • Product category:Ion Specific Electrode Meters
  • ULTRAPEN™ PT4
    • precision:0.3000 to 0.5000 ppm
    • ISE scope:0 to 10 ppm
    • Medium temperature:32 to 160 F (0 to 71 C)
    • Display type:Digital Display
    • Working temperature:32 to 131 F (0 to 55 C)
    • Appearance of the form:Hand Held
    • Features and functions:Battery Powered
    • Instrument features:Automatic Temperature Compensation
    • Product category:Ion Specific Electrode Meters
    • The water quality parameters:ISE Meter
  • HI 98172
    • precision:0.0100 ±pH
    • ISE scope:0 to 19990 ppm
    • The interface options:Serial
    • Display type:Video Display
    • User control:Digital Front Panel
    • Working temperature:32 to 122 F (0 to 50 C)
    • Appearance of the form:Hand Held
    • Features and functions:Battery Powered
    • Instrument features:Automatic Temperature Compensation
    • memory:Nonvolatile
    • ORP scope:-2000 to 2000 millivolts
    • Product category:Ion Specific Electrode Meters
    • The water quality parameters:ISE Meter; pH; Measures ORP/Redox
    • PH measurement features:Temperature Measurement
    • pH range:-2 to 16 pH
  • A-23.421.001.0
    • precision:-0.0100 to 0.1200 ppm
    • Number of electrodes:1
    • ISE scope:0 to 5 ppm
    • Medium temperature:-22 to 212 F (-30 to 100 C)
    • The number control relay:2
    • The electrical output:Analog Current
    • Display type:Digital Display
    • User control:Digital Front Panel
    • Working temperature:-13 to 149 F (-25 to 65 C)
    • Appearance of the form:Panel
    • Features and functions:Event Triggered
    • Instrument features:Automatic Temperature Compensation (optional feature)
    • Product category:Ion Specific Electrode Meters
    • The water quality parameters:ISE Meter; pH
    • PH measurement features:pH Reference Electrode Input (optional feature)
    • pH range:2 to 12 pH
  • ISEmax CAS40D
    • Number of electrodes:1
    • ISE scope:0 to 1000 ppm
    • Medium temperature:36 to 100 F (2 to 38 C)
    • Display type:None
    • User control:None
    • Working temperature:-4 to 120 F (-20 to 49 C)
    • Appearance of the form:In-situ / Field
    • Instrument features:Automatic Temperature Compensation
    • Product category:Ion Specific Electrode Meters
    • The water quality parameters:ISE Meter
  • CN Solution™ FS 3100
    • Number of electrodes:1
    • ISE scope:0 to 5 ppm
    • The interface options:Serial
    • Display type:None
    • User control:Computer Interface
    • Appearance of the form:Lab / Benchtop
    • Features and functions:Event Triggered
    • memory:Computer Required
    • Product category:Ion Specific Electrode Meters
    • Software support:PC
    • The water quality parameters:ISE Meter
  • FCL/CLD

    Sensorex Residual Chlorine/Chlorine Dioxide Sensor FCL/CLD

Filter Criteria

Filter Criteria

Appearance

Number Of Electrodes (Input)

#

ISE Scope

Accuracy

Control Relay Quantity

#

Electrical Output

Interface Options

Display Type

User Control

Medium Temperature

Operating Temperature

}