Filter Criteria

Switch Type

Measurement Technology

Switch Normal State

Number Of Poles

Measuring Medium

Medium Temperature

Accuracy

±%

Operating Temperature

Work Pressure

Electrical Output

Interface Options

Pipe Diameter

Installation Type

End Fittings

Feature

Filter Criteria

  • FS-200 Series
    • Switch type:Electro-Mechanical Switch
    • Toss a few:Double Throw
    • The number of:Single Pole
    • work pressure:400 psi (282 m H2O)
    • Medium temperature:-20 to 300 F (-29 to 149 C)
    • Measuring the dielectric:Liquid
    • Working temperature:-20 to 300 F (-29 to 149 C)
    • The terminal fittings:Threaded
    • Pipe diameter:1.00 to 2.00 inch (25.4 to 50.8 mm)
    • The installation:In-line
    • Product category:Volumetric Liquid Flow Switches
    • Audit certification:Underwriters Laboratory; Canadian Standards Association; CE, FM
    • The liquid volume flow:0.50 to 100.00 GPM (1.89 to 379 L/min)
    • Product standards:RoHS
    • The instrument type:Volumetric Flow Meter
  • FST-200-R & FST-300-R
    • precision:5 ±%
    • work pressure:150 psi (106 m H2O)
    • Medium temperature:158 F (70 C)
    • Measuring the dielectric:Liquid; Gas
    • Characteristics of the:Controller; Suspended Solids / Slurries
    • Working temperature:? to 140 F (? to 60 C)
    • The terminal fittings:Threaded
    • Pipe diameter:0.75 to 12.00 inch (19.05 to 305 mm)
    • The installation:In-line
    • Switch to normal:Normally Open; Normally Closed
    • Product standards:RoHS
    • Product category:Volumetric Liquid Flow Switches
    • The instrument type:Volumetric Flow Meter
  • Setra FS-10798 Series

    Total of 9 Product Data

    Click to View
    FS-10798 Series
    • Switch type:Electro-Mechanical Switch
    • Toss a few:Double Throw
    • The number of:Single Pole
    • work pressure:1000 psi (704 m H2O)
    • Measurement technology:Piston
    • Medium temperature:-20 to 300 F (-29 to 149 C)
    • Measuring the dielectric:Liquid
    • Working temperature:-20 to 300 F (-29 to 149 C)
    • The terminal fittings:Threaded
    • Pipe diameter:0.50 inch (12.7 mm)
    • The installation:In-line
    • Product category:Volumetric Liquid Flow Switches
    • The instrument type:Volumetric Flow Meter
    • The liquid volume flow:0.50 to 20.00 GPM (1.89 to 75.76 L/min)
    • Product standards:RoHS
    • Audit certification:Underwriters Laboratory; Canadian Standards Association; CE
  • 7000&8000 Series Differential Pressure Orifice Type Flow Meter
    • Switch type:Electro-Mechanical Switch
    • Toss a few:Double Throw
    • The number of:Single Pole
    • work pressure:10 to 400 psi (7.04 to 282 m H2O)
    • Measurement technology:Orifice Plates ;Thermal
    • Medium temperature:-30 to 350 F (-34 to 177 C)
    • Measuring the dielectric:Liquid; Gas; Steam
    • Characteristics of the:Recorder / Totalizer Functions
    • The electrical output:Analog Current;Frequency
    • Working temperature:-80 to 350 F (-62 to 177 C)
    • The terminal fittings:Threaded; Wafer
    • Pipe diameter:0.25 to 8.00 inch (6.35 to 203 mm)
    • The installation:In-line
    • Product category:Volumetric Liquid Flow Switches
    • The instrument type:Volumetric Flow Meter
    • Direct current voltage:175 volts
    • Ac voltage:125 volts
    • The liquid volume flow:2.00 to 500.00 GPM (7.58 to 1894 L/min)
    • current:0.2500 amps
    • According to:Analog
  • EZ-View® Flow Meters
    • precision:5 ±%
    • Switch type:Electro-Mechanical Switch
    • work pressure:325 psi (229 m H2O)
    • Measurement technology:Rotameter; Variable Area
    • Medium temperature:32 to 250 F (0 to 121 C)
    • Measuring the dielectric:Liquid; Gas
    • The terminal fittings:Threaded
    • Pipe diameter:0.50 to 1.00 inch (12.7 to 25.4 mm)
    • The installation:In-line
    • Switch to normal:Normally Open
    • The instrument type:Volumetric Flow Meter
    • Ac voltage:115 volts
    • current:25 amps
    • Direct current voltage:30 volts
    • Product category:Volumetric Liquid Flow Switches
    • The liquid volume flow:26.40 GPM (100 L/min)
  • Sitron CF12

    Total of 1 Product Data

    Click to View
    CF12
    • Switch type:Electro-Mechanical Switch
    • Toss a few:Double Throw
    • The number of:Single Pole
    • work pressure:1450 psi (1021 m H2O)
    • Measuring the dielectric:Liquid; Gas
    • Working temperature:14 to 176 F (-10 to 80 C)
    • The terminal fittings:Threaded
    • Pipe diameter:0.25 to 0.50 inch (6.35 to 12.7 mm)
    • The installation:In-line
    • The instrument type:Volumetric Flow Meter
    • The liquid volume flow:0.00 to 0.08 GPM (0.0030 to 0.3000 L/min)
    • Product category:Volumetric Liquid Flow Switches
    • current:5 amps
    • Ac voltage:250 volts
  • DF-WM - Paddle Wheel Flow Switch
    • precision:2.5 ±%
    • work pressure:85 to 1450 psi (59.82 to 1020 m H2O)
    • Measurement technology:Paddlewheel ;Other
    • Medium temperature:180 F (82 C)
    • Measuring the dielectric:Liquid
    • Working temperature:-10 to 180 F (-23 to 82 C)
    • The terminal fittings:Threaded
    • The installation:In-line
    • The instrument type:Volumetric Flow Meter
    • The liquid volume flow:0.02 to 36.00 GPM (0.0758 to 136 L/min)
    • Product category:Volumetric Liquid Flow Switches
  • Model 100CS
    • precision:1 ±%
    • Measurement technology:Thermal
    • Medium temperature:0 to 212 F (-18 to 100 C)
    • Measuring the dielectric:Liquid; Gas
    • Characteristics of the:Sanitary
    • Working temperature:0 to 120 F (-18 to 49 C)
    • The terminal fittings:Flanged ; Threaded; Sanitary
    • Pipe diameter:1.00 to ? inch (25.4 to ? mm)
    • The installation:Insertion
    • According to:Digital
    • Product category:Volumetric Liquid Flow Switches
    • The instrument type:Mass Flow Meter; Volumetric Flow Meter; Velocity Flow Meter
  • Plast-O-Matic FSA100

    Total of 8 Product Data

    Click to View
    FSA100
    • Measuring the dielectric:Liquid
    • The terminal fittings:Threaded
    • Pipe diameter:1.00 inch (25.4 mm)
    • The installation:In-line
    • The instrument type:Volumetric Flow Meter
    • Product category:Volumetric Liquid Flow Switches
  • FS10A
    • precision:0.5000 ±%
    • Switch type:Solid-State Switch
    • work pressure:0.0 to 600 psi (0.0 to 422 m H2O)
    • Measurement technology:Thermal
    • Medium temperature:-40 to 500 F (-40 to 260 C)
    • Measuring the dielectric:Liquid; Gas
    • Characteristics of the:Built-in Alarm Indicator
    • The electrical output:Analog Current
    • Working temperature:-40 to 160 F (-40 to 71 C)
    • The terminal fittings:Flanged; Threaded
    • Pipe diameter:0.25 to 0.50 inch (6.35 to 12.7 mm)
    • The installation:Insertion
    • Switch to normal:Normally Open
    • Product category:Volumetric Liquid Flow Switches
    • The instrument type:Volumetric Flow Meter
    • Audit certification:ATEX; FM, FMc, IECEx, CE Mark, CRN, ANSI / ISA 12.27.01-2011, SIL
    • The liquid volume flow:0.00 to 0.03 GPM (0.0038 to 0.1136 L/min)
    • Additional variable measurement:Temperature
    • Direct current voltage:24 volts
Filter Criteria

Filter Criteria

Switch Type

Measurement Technology

Switch Normal State

Number Of Poles

Measuring Medium

Medium Temperature

Accuracy

±%

Operating Temperature

Work Pressure

Electrical Output

Interface Options

Pipe Diameter

Installation Type

End Fittings

Feature

}