  • 200005500
    • Switch type:Electro-Mechanical Switch
    • work pressure:3600 psi (2534 m H2O)
    • Medium temperature:176 F (80 C)
    • Measuring the dielectric:Liquid
    • The terminal fittings:Threaded
    • Pipe diameter:0.38 inch (9.52 mm)
    • The installation:In-line
    • The instrument type:Volumetric Flow Meter
    • The liquid volume flow:1.00 to 8.00 GPM (3.79 to 30.3 L/min)
    • Ac voltage:400 volts
    • current:3 amps
    • Product category:Volumetric Liquid Flow Switches
  • W-BB-DDS-03B-B
    • work pressure:150 psi (106 m H2O)
    • Measurement technology:Turbine ;Other
    • Measuring the dielectric:Liquid
    • Working temperature:-32 to 180 F (-36 to 82 C)
    • The terminal fittings:Threaded
    • The installation:In-line
    • The liquid volume flow:0.00 to 7.92 GPM (0.0 to 30 L/min)
    • Additional variable measurement:Temperature
    • Panel interface:Digital Front Panel
    • Product category:Volumetric Liquid Flow Switches
    • The instrument type:Volumetric Flow Meter
    • According to:Digital
  • Volker Automation FXW

    Total of 3 Product Data

    Click to View
    FXW

    Volker Automation FXW Liquid Flow Switch

  • Liquid level detection LS 0155

    Lingtu Sensing Liquid Level Detection LS 0155 Liquid Flow Switch

  • FS-IR12 water tank water level control photoelectric liquid level water level alarm liquid level sensor anti-overflow tank hand washing

    Nengdian Technology EPT FS-IR12 water tank water level control photoelectric liquid level water level alarm liquid level sensor anti-overflow cylinder hand washing liquid flow switch

  • 1020N & 1024N & 1026N & 1027N
    • Switch Type:Electro-Mechanical Switch
    • Toss A Few:Double Throw
    • The Number Of:Single Pole
    • Work Pressure:75 to 500 psi (52.78 to 352 m H2O)
    • Measurement Technology:Rotameter; Variable Area
    • Medium Temperature:250 F (121 C)
    • Measuring The Dielectric:Liquid; Gas
    • Characteristics Of The:Built-in Alarm Indicator
    • Working Temperature:33 to 250 F (1 to 121 C)
    • The Terminal Fittings:Threaded
    • The Installation:In-line
    • The Liquid Volume Flow:98.00 GPM (371 L/min)
    • The Instrument Type:Volumetric Flow Meter
    • Product Category:Volumetric Liquid Flow Switches
  • FlexSwitch® FLT93B-B*00
    • precision:0.5000 ±%
    • Switch type:Electro-Mechanical Switch
    • Toss a few:Double Throw
    • The number of:Single Pole; Double Pole
    • work pressure:0.0 to 3500 psi (0.0 to 2463 m H2O)
    • Measurement technology:Thermal
    • Medium temperature:-40 to 350 F (-40 to 177 C)
    • Measuring the dielectric:Liquid; Gas
    • The electrical output:Analog Voltage
    • Working temperature:-40 to 140 F (-40 to 60 C)
    • The terminal fittings:Threaded
    • Pipe diameter:0.75 inch (19.05 mm)
    • The installation:Insertion
    • Ac voltage:240 volts
    • The instrument type:Mass Flow Meter; Volumetric Flow Meter; Velocity Flow Meter
    • current:6 amps
    • Audit certification:ATEX; IEC, IECEx, NFPA Code 30 Compliance
    • Product category:Volumetric Liquid Flow Switches
    • Direct current voltage:24 volts
    • Additional variable measurement:Temperature; Level
  • FS-200 Series
    • Switch type:Electro-Mechanical Switch
    • Toss a few:Double Throw
    • The number of:Single Pole
    • work pressure:400 psi (282 m H2O)
    • Medium temperature:-20 to 300 F (-29 to 149 C)
    • Measuring the dielectric:Liquid
    • Working temperature:-20 to 300 F (-29 to 149 C)
    • The terminal fittings:Threaded
    • Pipe diameter:1.00 to 2.00 inch (25.4 to 50.8 mm)
    • The installation:In-line
    • Product category:Volumetric Liquid Flow Switches
    • Audit certification:Underwriters Laboratory; Canadian Standards Association; CE, FM
    • The liquid volume flow:0.50 to 100.00 GPM (1.89 to 379 L/min)
    • Product standards:RoHS
    • The instrument type:Volumetric Flow Meter
  • FL-6300
    • precision:2 ±%
    • Toss a few:Double Throw
    • The number of:Single Pole
    • work pressure:1000 to 3500 psi (704 to 2463 m H2O)
    • Medium temperature:241 F (116 C)
    • Measuring the dielectric:Liquid; Gas
    • Characteristics of the:Built-in Alarm Indicator
    • Working temperature:? to 241 F (? to 116 C)
    • The terminal fittings:Threaded
    • Pipe diameter:0.50 to 0.75 inch (12.7 to 19.05 mm)
    • The installation:In-line
    • Product standards:RoHS
    • Product category:Volumetric Liquid Flow Switches
    • The instrument type:Volumetric Flow Meter
    • The liquid volume flow:0.10 to 30.00 GPM (0.3788 to 114 L/min)
    • According to:Analog
  • 1020N & 1024N & 1026N & 1027N
    • Switch type:Electro-Mechanical Switch
    • Toss a few:Double Throw
    • The number of:Single Pole
    • work pressure:75 to 500 psi (52.78 to 352 m H2O)
    • Measurement technology:Rotameter; Variable Area
    • Medium temperature:250 F (121 C)
    • Measuring the dielectric:Liquid; Gas
    • Characteristics of the:Built-in Alarm Indicator
    • Working temperature:33 to 250 F (1 to 121 C)
    • The terminal fittings:Threaded
    • The installation:In-line
    • The liquid volume flow:98.00 GPM (371 L/min)
    • The instrument type:Volumetric Flow Meter
    • Product category:Volumetric Liquid Flow Switches