Filter Criteria

Implementation Modalities

Reset/Release Operation

Pull Cord (Rope) Characteristics

Number Of Normally Open Contacts

#

Number Of Normally Closed Contacts

#

Number Of Conversion Contacts

#

Maximum Rated Current

Maximum AC Voltage Rating

Maximum DC Voltage Rating

Feature

Operating Temperature

Pressure Range

Filter Criteria

  • RS Components 321155

    Total of 20 Product Data

    Click to View
    321155
    • Normally open contact points:1 #
    • The normally closed contact points:1 #
    • Reset/release operation:Pull to Reset
    • Maximum rated current:16 amps
    • Implement way:Pushbutton
    • Product category:Emergency Stop Switches
  • Farnell Newark 08R7300

    Total of 188 Product Data

    Click to View
    08R7300
    • Maximum ac rated voltage:24 volts
    • The largest dc rated voltage:24 volts
    • Maximum rated current:0.0080 amps
    • Implement way:Pushbutton
    • Product category:Emergency Stop Switches
  • 800H-1HA7
    • Implement way:Pushbutton
    • Product category:Emergency Stop Switches
  • Eaton M22-PVL

    Total of 7 Product Data

    Click to View
    M22-PVL
    • Reset/release operation:Pull to Reset
    • Characteristics of the:Illuminated Pushbutton
    • Implement way:Pushbutton
    • manufacturers:Eaton-ePDU®
    • Product model:M22-PVL
    • Product category:Emergency Stop Switches
  • Schmersal Series ZSD

    Total of 3 Product Data

    Click to View
    Series ZSD
    • Reset/release operation:Pushbutton
    • The largest dc rated voltage:500 volts
    • Maximum rated current:4 amps
    • Working temperature:-13 to 140 F (-25 to 60 C)
    • Implement way:Pushbutton
    • Contact choice:Positive Break
    • Mechanical life:1000000 (#)
    • Operating force:20 N (71.94 oz)
    • Product category:Emergency Stop Switches
    • Switch type:Electrical
  • RAFI RAFIX 22 FS+

    Total of 6 Product Data

    Click to View
    RAFIX 22 FS+
    • The normally closed contact points:2 #
    • Reset/release operation:Pull to Reset; Twist to Reset
    • Maximum ac rated voltage:250 volts
    • The largest dc rated voltage:250 volts
    • Maximum rated current:4 amps
    • Working temperature:-13 to 158 F (-25 to 70 C)
    • Implement way:Pushbutton
    • Auxiliary (not secure) output:1 (#)
    • International Certification:RoHS, REACH, TUV, UL, CCC, VDE
    • Mechanical life:50000 (#)
    • Product category:Emergency Stop Switches
    • Switch type:Electrical
  • Schaltbau S 134 1-00

    Total of 1 Product Data

    Click to View
    S 134 1-00
    • The normally closed contact points:1 #
    • Reset/release operation:Pushbutton
    • Characteristics of the:Lockable
    • The largest dc rated voltage:100 volts
    • Maximum rated current:1500 amps
    • NEMA enclosure rating:IP00
    • Mechanical life:30000 (#)
    • perform:Pushbutton
    • Switch type:Electrical
    • Product category:Emergency Stop Switches
  • 3SU1001-1HB20-0AA0
    • Reset/release operation:Twist to Reset
    • Characteristics of the:Illuminated Pushbutton
    • Implement way:Pushbutton
    • manufacturers:Siemens Corporation
    • Product model:3SU1001-1HB20-0AA0
    • Product category:Emergency Stop Switches
  • EAO 704.074.3

    Total of 6 Product Data

    Click to View
    704.074.3
    • Maximum ac rated voltage:500 volts
    • The largest dc rated voltage:500 volts
    • Maximum rated current:10 amps
    • Implement way:Pushbutton
    • International Certification:IP65
    • manufacturers:EAO Switch Corporation
    • Product model:704.074.3
    • Product category:Emergency Stop Switches
  • HK-Micronor387 series
    • Normal reset (upper):Red LED lights;
    • Activation (lower):Red LED lights up
    • Damage of optical fiber, optical signals:The number 5 v and 24 v output = LOW
    • Lost or controller failure:Relay contact = open NC, relay contact = NO closed
    • Interface:Duplex LC for tail fiber MR387 - XX - YY YY refers to the tail fiber, the unit is m) ODVA IP - LC connection socket, m
    • The temperature:To 40 ° C to + 65 ° C (to 40 ° F to 150 ° F) +, 0-95% RH, the condensation
Filter Criteria

Filter Criteria

Implementation Modalities

Reset/Release Operation

Pull Cord (Rope) Characteristics

Number Of Normally Open Contacts

#

Number Of Normally Closed Contacts

#

Number Of Conversion Contacts

#

Maximum Rated Current

Maximum AC Voltage Rating

Maximum DC Voltage Rating

Feature

Operating Temperature

Pressure Range

}