  • SKF TMTP 200Ex

    Total of 2 Product Data

    Click to View
    TMTP 200Ex
    • Induction temperature range:-40 to 392 F (-40 to 200 C)
    • C range:-40 to 200 C (-40 to 392 F)
    • C shows:Celsius/ Centigrade (optional feature)
    • Fahrenheit display area:-40 to 392 F (-40 to 200 C)
    • The input options:PermanPermanent Sensor or the Probe/permanent Sensor or Sensor
    • Fahrenheit temperature display:Fahrenheit (optional feature)
    • Local interface:Digital Front Panel
    • According to:Digital Readouts
    • installation:Portable or Hand by/Portable/handheld
    • C/c scale:1 deg C
    • application:Explosion Proof; Splash Proof, Watertight or Direct Immersion
    • # of Inputs / Channels:1 #
    • Thermocouple type:K
    • Fahrenheit scale:1 deg F
    • Product category:Temperature Indicators
    • Characteristics of the:Battery Powered; Detachable Probes
  • 5-Point “Clock” Multipoint Indicators
    • installation:Other
    • Product category:Temperature Indicators
  • Model 372 AC
    • Local interface:Digital Front Panel
    • Communication interface:Serial Interface
    • According to:Digital Readouts
    • installation:Self-Contained/Stand Alone Instrument ;
    • Product category:Temperature Indicators
  • Conax 5714

    Total of 2 Product Data

    Click to View
    5714
    • Induction temperature range:-200 to 2300 F (-129 to 1260 C)
    • C range:9999 C (18030 F)
    • C shows:Celsius/ Centigrade
    • The input options:Thermocouple Inputs; Accepts RTD Inputs
    • Local interface:Digital Front Panel
    • According to:Digital Readouts
    • installation:Panel Mount
    • Alternating current:Measures AC Current
    • Ac voltage:Accepts AC Voltage Inputs
    • AC voltage range:21.6 to 253 volts
    • Additional output:Outputs an analog current signal;
    • application:Splash Proof, Watertight or Direct Immersion (optional feature)
    • Dc current:Measures DC Current
    • Direct current voltage:Measures DC Voltages
    • Dc voltage range:19.2 to 300 volts
    • Electric resistance probe:10 Ohms to 100 kOhms
    • Product category:Temperature Indicators
    • Reference material:Platinum; Nickel/Nickel Alloys
    • Thermocouple type:E; J; K; N; T; B; S; R; W
  • Pyromation Series 610

    Total of 3 Product Data

    Click to View
    Series 610
    • C shows:Celsius/ Centigrade
    • The input options:Thermocouple Inputs; Accepts RTD Inputs
    • Fahrenheit temperature display:Fahrenheit
    • Local interface:Digital Front Panel
    • Communication interface:Serial Interface
    • Computer interface:Computer Interface
    • According to:Digital Readouts
    • installation:Portable or Hand Held; Self-Contained/Stand Alone Instrument
    • Direct current voltage:Measures DC Voltages
    • Product category:Temperature Indicators
    • Reference material:Platinum
    • Characteristics of the:Some Controller Functionality (ex. set limits, regulator, P/PI/PID etc.); Datalogger; Min/Max Recorder
    • Dc voltage range:0.0 to 10 volts
    • Dc current:Measures DC Current
    • Additional output:Outputs an analog current signal
    • Current range:0.0 to 20 milliamps
    • Thermocouple type:J; K; N; T; B; S; R
    • Electric resistance probe:3 wire Pt100
  • ENVIROSEAL RTD Sensors
    • The input options:RTD Inputs
    • The input/channel:1 #
    • According to:None - No Display
    • installation:Portable or Hand Held; Self-Contained/Stand Alone Instrument
    • Reference material:Platinum
    • Product category:Temperature Indicators
  • ifm TP3231

    Total of 58 Product Data

    Click to View
    TP3231
    • Induction temperature range:-58 to 572 F (-50 to 300 C)
    • Product category:Temperature Indicators
    • Additional output:Outputs an analog current signal
  • TAG130AG4
    • C range:-40 to 40 C (-40 to 104 F)
    • C shows:Celsius/ Centigrade
    • Fahrenheit display area:-40 to 110 F (-40 to 43.33 C)
    • The input options:Permanent Sensor or Probe
    • Fahrenheit temperature display:Fahrenheit
    • According to:Analog Meter or Indicator
    • installation:Portable or Hand Held; Self-Contained/Stand Alone Instrument
    • Product category:Temperature Indicators
    • Including the probe thermometer or size:4.5" Straight
    • application:HVAC
    • # of Inputs / Channels:1 #
  • EnviroAlert® EA200
    • Induction temperature range:-58 to 299 F (-50 to 148 C)
    • The input options:Thermistor Inputs
    • The input/channel:1 #
    • Fahrenheit temperature display:Fahrenheit
    • Local interface:Digital Front Panel
    • According to:Digital Readouts
    • Product category:Temperature Indicators
  • 3200 Single Loop Indicator & Controller (Partlow)
    • The input options:Thermocouple Inputs; Accepts RTD Inputs
    • Local interface:Digital Front Panel
    • Communication interface:Serial Interface
    • Computer interface:Computer Interface
    • According to:Digital Readouts
    • installation:Rail or Track Mounted
    • Direct current voltage:Measures DC Voltages
    • Current range:0.0 to 20 milliamps
    • Thermocouple type:J; K; N; T; B; S; R
    • Additional output:"Output" is a switch or alarm signal
    • Product category:Temperature Indicators
    • Electric resistance probe:100 Ohm
    • Dc voltage range:0.0 to 0.0500 volts
    • Dc current:Measures DC Current
    • Reference material:Platinum
    • Characteristics of the:Some Controller Functionality (ex. set limits, regulator, P/PI/PID etc.)