Filter Criteria

Product Type

Measurement Technology

Measurement Type

Mass Flow

Gas Flow Rate

Gas Volume Flow

Accuracy

±% Full Scale

Output Options

Air Pressure Range

Operating Temperature

Installation Form

Filter Criteria

  • RS Components 1232224

    Total of 4 Product Data

    Click to View
    1232224
    • precision:3 ±% Full Scale
    • Gas flow speed range:5906 to 6015 SFPM (3000 to 3056 cm/s)
    • Product category:Air Flow Sensors
    • Speed resolution:0.8800 to 19.69 SFPM (0.4470 to 10 cm/s)
  • FMA900A
    • precision:2 ±% Full Scale
    • Gas flow speed range:0.0 to 12000 SFPM (0.0 to 6096 cm/s)
    • Technical types:Thermal Anemometer
    • Output options:Outputs an analog voltage signal; Outputs an analog current signal; "Output" is a switch or alarm signal
    • Working temperature:-40 to 250 F (-40 to 121 C)
    • The installation:Hand-held or Portable
    • Measuring type:Air Velocity
    • The instrument type:Insertion Probe Type
    • Characteristics of the:Audible or Visual Alarm; Selectable Range
    • Pipe diameter:0.2500 inch (6.35 mm)
    • The length of the probe:12 inch (305 mm)
    • Product category:Air Flow Sensors
  • TSI Incorporated PVM610

    Total of 19 Product Data

    Click to View
    PVM610
    • Measuring type:Air Velocity; Air Pressure Differential
    • Product category:Air Flow Sensors
  • E+E Elektronik EE671

    Total of 1 Product Data

    Click to View
    EE671
    • Gas flow speed range:0.0 to 3937 SFPM (0.0 to 2000 cm/s)
    • Technical types:Thermal Anemometer
    • Output options:Outputs an analog voltage signal
    • Working temperature:-4 to 140 F (-20 to 60 C)
    • The installation:Fixtured or Permanent
    • Measuring type:Air Velocity
    • The instrument type:Insertion Probe Type
    • Pipe diameter:0.4724 inch (12 mm)
    • Product category:Air Flow Sensors
  • Dwyer Model DAFM Duct Air Flow Measuring Probe
    • precision:2 ±% Full Scale
    • Gas flow speed range:400 to 12000 SFPM (203 to 6096 cm/s)
    • Technical types:Differential Pressure
    • Working temperature:? to 400 F (? to 204 C)
    • The installation:Fixtured or Permanent
    • Measuring type:Air Velocity
    • The instrument type:Insertion Probe Type
    • Product category:Air Flow Sensors
Filter Criteria

Filter Criteria

Product Type

Measurement Technology

Measurement Type

Mass Flow

Gas Flow Rate

Gas Volume Flow

Accuracy

±% Full Scale

Output Options

Air Pressure Range

Operating Temperature

Installation Form

}