Filter Criteria

Instrument Type

Measuring Medium

Medium Temperature

Mass Flow

Gas Volume Flow

Liquid Volume Flow

Accuracy

±%

Electrical Output

Interface Options

Pipe Diameter

Work Pressure

Operating Temperature

Installation Type

End Fittings

Feature

Filter Criteria

Mass Flowmeter & The Controller

  • FST-320
    • precision:5 ±%
    • work pressure:150 psi (106 m H2O)
    • Medium temperature:140 F (60 C)
    • Medium type:Gas
    • The terminal fittings:In-line Threaded
    • Pipe diameter:0.75 inch (19.05 mm)
    • The installation:Insertion Type
    • Instrument in the form of:Mass Flow Meter; Velocity Flow Meter
    • Measurement technology:Thermal
    • Product category:Mass Flow Meters and Controllers
    • Product standards:RoHS
  • 5220-2
    • Mass Flow:0.0 to 0.0826 lbs/min (0.0 to 0.0022 metric tons/hr)
    • Medium type:Gas
    • Instrument in the form of:Mass Flow Meter
    • Product category:Mass Flow Meters and Controllers
  • Gas Flow Meters- SmartTrak® 100-M
    • precision:1 ±%
    • work pressure:5000 psi (3519 m H2O)
    • The gas volume flow:0.0 to 7.06 SCFM (0.0 to 12 m³/hr)
    • Medium temperature:32 to 122 F (0 to 50 C)
    • Medium type:Gas
    • Characteristics of the:Controller (optional feature); Programmable; Recorder / Totalizer Functions
    • The electrical output:Analog Current; Voltage
    • The interface options:Serial / Digital ; RS-232, RS-485 (optional), Profibus DP, Modbus, Foundation Fieldbus
    • Working temperature:32 to 122 F (0 to 50 C)
    • The terminal fittings:Compression (optional feature); In-line Threaded (optional feature); VCO® / VCR® (optional feature)
    • Pipe diameter:0.25 to 0.75 inch (6.35 to 19.05 mm)
    • The installation:In-line
    • Instrument in the form of:Mass Flow Meter; Volumetric Flow Meter
    • Audit certification:CE, CRN, ISO 9001
    • current:0.2300 to 1.26 amps
    • Direct current voltage:24 volts
    • According to:Digital (optional feature)
    • The front panel interface:Digital Front Panel (optional feature); Computer Controllable (optional feature)
    • Measurement technology:Thermal
    • Product category:Mass Flow Meters and Controllers
    • Product standards:RoHS; WEEE Compliant
  • Series F-107AI&&DI
    • Mass Flow:0.0184 to 82.59 lbs/min (4.99E-4 to 2.25 metric tons/hr)
    • work pressure:0.0 to 928 psi (0.0 to 653 m H2O)
    • The gas volume flow:0.2352 to 1058 SCFM (0.3998 to 1799 m³/hr)
    • Medium temperature:14 to 158 F (-10 to 70 C)
    • Medium type:Gas
    • Characteristics of the:Controller (optional feature); Recorder / Totalizer Functions
    • The electrical output:Analog Current; Voltage
    • The interface options:Serial / Digital;Network / Fieldbus
    • Working temperature:32 to 158 F (0 to 70 C)
    • The terminal fittings:In-line Flanged
    • The installation:In-line
    • Instrument in the form of:Mass Flow Meter; Volumetric Flow Meter
    • Product category:Mass Flow Meters and Controllers
    • Audit certification:ATEX
    • Measurement technology:Thermal
    • Product standards:RoHS
    • According to:Digital (optional feature)
    • The front panel interface:Computer Controllable
  • ValuMass™ 400
    • work pressure:500 psi (352 m H2O)
    • Medium temperature:-40 to 392 F (-40 to 200 C)
    • Medium type:Gas
    • The electrical output:Analog Current; Frequency (optional feature); Voltage
    • The interface options:Serial / Digital; Network / Fieldbus (optional feature)
    • Working temperature:-40 to 158 F (-40 to 70 C)
    • The terminal fittings:In-line Threaded
    • Pipe diameter:0.25 to 2.00 inch (6.35 to 50.8 mm)
    • The installation:In-line
    • Instrument in the form of:Mass Flow Meter
    • Additional variable measurement:Temperature
    • Audit certification:CE
    • According to:Digital
    • Measurement technology:Thermal
    • Product category:Mass Flow Meters and Controllers
  • FS6122 Bi-Directional Medical Respiratory Sensor
    • Mass Flow:-0.6883 to 0.6883 lbs/min (-0.0187 to 0.0187 metric tons/hr)
    • Instrument in the form of:Mass Flow Meter
    • Product category:Mass Flow Meters and Controllers
  • LF-F&LV-F Series
    • Mass Flow:4.41E-5 to 0.2205 lbs/min (1.20E-6 to 0.0060 metric tons/hr)
    • work pressure:725 psi (510 m H2O)
    • Medium type:Liquid
    • Characteristics of the:Controller Functions
    • The electrical output:Analog Voltage
    • The interface options:Serial / Digital
    • Working temperature:41 to 122 F (5 to 50 C)
    • The terminal fittings:Compression; VCO® / VCR®
    • Pipe diameter:0.06 to 0.25 inch (1.59 to 6.35 mm)
    • The installation:In-line
    • Instrument in the form of:Mass Flow Meter
    • Product category:Mass Flow Meters and Controllers
    • Measurement technology:Peltier element used to cool the liquid
  • DFM 26
    • precision:1 ±%
    • work pressure:0.0 to 100 psi (0.0 to 70.38 m H2O)
    • Medium temperature:41 to 122 F (5 to 50 C)
    • Medium type:Gas
    • Characteristics of the:Built-in Alarm Indicator; Multi-insertion; Controller; Recorder / Totalizer Functions
    • The electrical output:Current (optional feature); Switch (optional feature); Voltage (optional feature)
    • The interface options:Serial / Digital
    • Working temperature:41 to 122 F (5 to 50 C)
    • The terminal fittings:Compression
    • Pipe diameter:0.12 to 0.38 inch (3.17 to 9.52 mm)
    • The installation:In-line
    • Instrument in the form of:Mass Flow Meter
    • The front panel interface:Digital Front Panel; Computer Controllable
    • Product category:Mass Flow Meters and Controllers
    • According to:Digital
    • Measurement technology:Thermal
  • Digital Mass Flow Meter
    • work pressure:250 psi (176 m H2O)
    • Medium temperature:32 to 122 F (0 to 50 C)
    • Medium type:Gas
    • Working temperature:32 to 122 F (0 to 50 C)
    • The terminal fittings:In-line Threaded
    • The installation:In-line
    • Instrument in the form of:Mass Flow Meter; Volumetric Flow Meter
    • Additional variable measurement:Temperature
    • According to:Digital
    • The front panel interface:Digital Front Panel
    • Product category:Mass Flow Meters and Controllers
  • A series AMF006A/008AN/025AN/050A/080A

    Andisoon Measurement A series AMF006A/008AN/025AN/050A/080A mass flow meter and controller

Filter Criteria

Filter Criteria

Instrument Type

Measuring Medium

Medium Temperature

Mass Flow

Gas Volume Flow

Liquid Volume Flow

Accuracy

±%

Electrical Output

Interface Options

Pipe Diameter

Work Pressure

Operating Temperature

Installation Type

End Fittings

Feature

}