Filter Criteria

Instrument Type

Measuring Medium

Medium Temperature

Mass Flow

Gas Volume Flow

Liquid Volume Flow

Accuracy

±%

Electrical Output

Interface Options

Pipe Diameter

Work Pressure

Operating Temperature

Installation Type

End Fittings

Feature

Filter Criteria

Mass Flowmeter & The Controller

  • FSS430
    • precision:0.5000 ±%
    • work pressure:218 to 5802 psi (153 to 4083 m H2O)
    • Medium temperature:-67 to 536 F (-55 to 280 C)
    • Medium type:Liquid; Gas; Steam
    • Characteristics of the:Programmable
    • The electrical output:Analog Current
    • The interface options:Serial / Digital
    • Working temperature:-40 to 185 F (-40 to 85 C)
    • The terminal fittings:In-line Flanged
    • Pipe diameter:0.50 to 16.00 inch (12.7 to 406 mm)
    • The installation:In-line
    • Instrument in the form of:Mass Flow Meter; Volumetric Flow Meter; Velocity Flow Meter
    • Additional variable measurement:Temperature
    • Audit certification:ATEX; IECEx, FM, NEPSI, MID/OIML R117
    • According to:Digital
    • The front panel interface:Digital Front Panel
    • Product category:Mass Flow Meters and Controllers
  • CNGmass
    • Product category:Mass Flow Meters and Controllers
    • Measurement technology:Coriolis
    • Audit certification:CE, C-tick, Ex Approvals
    • Mass Flow:0.0 to 330 lbs/min (0.0 to 8.98 metric tons/hr)
    • work pressure:5080 psi (3575 m H2O)
    • Medium temperature:-58 to 257 F (-50 to 125 C)
    • Medium type:Gas
    • The electrical output:Frequency; Switch
    • The interface options:Network / Fieldbus
    • Working temperature:-40 to 140 F (-40 to 60 C)
    • The terminal fittings:In-line Flanged
    • Pipe diameter:0.38 to 1.00 inch (9.52 to 25.4 mm)
    • The installation:In-line
    • Instrument in the form of:Mass Flow Meter
    • Additional variable measurement:Temperature; Density
  • OPTISONIC 7300 Biogas
    • precision:1.5 ±%
    • work pressure:145 psi (102 m H2O)
    • Medium temperature:-40 to 212 F (-40 to 100 C)
    • Medium type:Gas
    • Characteristics of the:Controller; Recorder / Totalizer Functions
    • The electrical output:Analog Current; Frequency
    • The interface options:Serial / Digital; Network / Fieldbus; Pulse, HART, Foundation Fieldbus, Modbus RS 485
    • Working temperature:-40 to 212 F (-40 to 100 C)
    • The terminal fittings:In-line Flanged
    • Pipe diameter:2.00 to 8.00 inch (50.8 to 203 mm)
    • The installation:In-line
    • Instrument in the form of:Mass Flow Meter; Volumetric Flow Meter; Velocity Flow Meter
    • Additional variable measurement:Temperature; Density
    • Audit certification:ATEX; Underwriters Laboratory; CE, Ex, IECEx, IEC, NEMA, NE
    • According to:Digital
    • Product category:Mass Flow Meters and Controllers
  • MutiTrak™ 670S Immersible Thermal Flow Meter
    • precision:1.5 ±%
    • work pressure:150 to 1000 psi (106 to 704 m H2O)
    • Medium temperature:-40 to 750 F (-40 to 399 C)
    • Medium type:Gas
    • Characteristics of the:Built-in Alarm Indicator; Multi-insertion; Programmable (optional feature); Recorder / Totalizer Functions
    • The electrical output:Analog Current
    • The interface options:Serial / Digital; Network / Fieldbus (optional feature); Modbus, Foundation Fieldbus, Profibus DP, HART
    • Working temperature:-40 to 120 F (-40 to 49 C)
    • The terminal fittings:Compression (optional feature); In-line Flanged (optional feature); Hot Tap
    • Pipe diameter:72.00 inch (1829 mm)
    • The installation:Insertion Type
    • Instrument in the form of:Mass Flow Meter; Velocity Flow Meter
    • Audit certification:ATEX; Canadian Standards Association; CE, FM, IP65, NEMA, Chinese Pattern, GOST R/RTN, ISO 9001
    • current:0.8250 amps
    • Direct current voltage:18 to 30 volts
    • According to:Digital
    • The front panel interface:Digital Front Panel
    • Measurement technology:Thermal
    • Product category:Mass Flow Meters and Controllers
    • Product standards:RoHS; WEEE Compliant
  • MT100S
    • precision:0.7500 ±%
    • work pressure:0.0 to 1000 psi (0.0 to 704 m H2O)
    • Medium temperature:850 F (454 C)
    • Medium type:Gas
    • Characteristics of the:Multi-insertion; Programmable
    • The electrical output:Analog Current; Switch; Voltage
    • The interface options:Serial / Digital;Network / Fieldbus
    • Working temperature:-40 to 150 F (-40 to 66 C)
    • The terminal fittings:Compression (optional feature); In-line Flanged (optional feature); NPT, ANSI, or DIN Flange
    • Pipe diameter:0.75 to 1.25 inch (19.05 to 31.75 mm)
    • The installation:Insertion Type
    • Instrument in the form of:Mass Flow Meter
    • Audit certification:ATEX; NEMA, ISO/IEC, NIST, CRN, US EPA CEMS(Optional)
    • The front panel interface:Digital Front Panel
    • Measurement technology:Thermal
    • Product category:Mass Flow Meters and Controllers
  • FS6122 Bi-Directional Medical Respiratory Sensor
    • Mass Flow:-0.6883 to 0.6883 lbs/min (-0.0187 to 0.0187 metric tons/hr)
    • Instrument in the form of:Mass Flow Meter
    • Product category:Mass Flow Meters and Controllers
  • LF-F&LV-F Series
    • Mass Flow:4.41E-5 to 0.2205 lbs/min (1.20E-6 to 0.0060 metric tons/hr)
    • work pressure:725 psi (510 m H2O)
    • Medium type:Liquid
    • Characteristics of the:Controller Functions
    • The electrical output:Analog Voltage
    • The interface options:Serial / Digital
    • Working temperature:41 to 122 F (5 to 50 C)
    • The terminal fittings:Compression; VCO® / VCR®
    • Pipe diameter:0.06 to 0.25 inch (1.59 to 6.35 mm)
    • The installation:In-line
    • Instrument in the form of:Mass Flow Meter
    • Product category:Mass Flow Meters and Controllers
    • Measurement technology:Peltier element used to cool the liquid