Filter Criteria

Instrument Type

Appearance And Installation Type

Measurement Type

Gas Classification

Gas Type

Number Of Channels

#

Response Time

Electrical Output

Show

Operating Temperature

Working Humidity

%

Feature

Application

Filter Criteria

  • RS Components 1346605

    Total of 7 Product Data

    Click to View
    1346605
    • Response Time:60 seconds
    • Working temperature:23 to ? F (-5 to ? C)
    • Type of gas:CO
    • The instrument type:Detector
    • Product category:Gas Instruments
  • 854301-1
    • The instrument type:Monitor
    • Product category:Gas Instruments
  • EC-Gold Dual
    • The electrical output:Current
    • According to:Digital
    • Working temperature:-4 to 104 F (-20 to 40 C)
    • Installation type:Fixed
    • Measuring type:%Volume; Trace
    • Type of gas:Toxic; CO (0-500ppm); Cl2 (0-10ppm); H2S (0-100ppm); NO2 (0-20ppm); O2 (0-30%)
    • The instrument type:Detector; Monitor
    • application:Ambient Air Monitoring
    • Product category:Gas Instruments
    • Number of Gases Monitored:Multi
    • Characteristics of the:Audible or Visual Alarms; Controller
  • CO2-EN Series
    • The channel number:1
    • Characteristics of the:Audible or Visual Alarms; Controller
    • The electrical output:Analog Current;Switch
    • According to:Digital
    • Working temperature:32 to 120 F (0 to 49 C)
    • Installation type:Fixed
    • Measuring type:Trace
    • Type of gas:Toxic; CO2
    • The instrument type:Monitor
    • application:Confined Space Entry
    • Product category:Gas Instruments
    • Monitoring gas quantity:Multi
    • Sensitivity technology:Infrared
  • INNOVA 1314i
    • Response Time:150 seconds
    • The channel number:24
    • Characteristics of the:Audible or Visual Alarms; Data Logger
    • According to:Digital
    • Working temperature:41 to 104 F (5 to 40 C)
    • Working humidity:80 %
    • Installation type:Fixed
    • Measuring type:Trace
    • Type of gas:Toxic; CO2 (1.5 ppm); Refrigerants (0.01 ppm); NxOx (N2O: 0.03 ppm); SF6 (0.006 ppm) (Halothane, Isoflurane, Methyl Methacrylate (MMA))
    • The instrument type:Monitor
    • application:Continuous Emissions Monitoring; Ambient Air Monitoring; Process Gas
    • Product category:Gas Instruments
    • Sensitivity technology:Infrared
    • Number of Gases Monitored:Multi
  • CA1510
    • Type of gas:CO2
    • manufacturers:Chauvin Arnoux Group
    • Product model:CA1510
    • Product category:Gas Instruments
  • MSA TRIGARD®

    Total of 5 Product Data

    Click to View
    TRIGARD®
    • Characteristics of the:Audible or Visual Alarms
    • The electrical output:Current
    • According to:Digital
    • Working temperature:14 to 104 F (-10 to 40 C)
    • Installation type:Fixed
    • Type of gas:Toxic; Combustible; O2
    • The instrument type:Monitor
    • application:Ambient Air Monitoring
    • Product category:Gas Instruments
  • CTD&CLD Series
    • According to:Digital
    • Working temperature:14 to 131 F (-10 to 55 C)
    • Measuring type:Trace
    • Type of gas:Toxic; CO2 (100ppm, 0-500ppm); H2S (0-100ppm)
    • The instrument type:Detector
    • application:Ambient Air Monitoring
    • Sensitivity technology:Electrochemical
    • Product category:Gas Instruments
    • Number of Gases Monitored:Multi
  • SGA-501/502/503/504/506 series

    Fixed all-in-one gas alarm, combustible gas/poisonous and harmful gases, optionally matched with 1-6 types of gases

  • XF-EGS8000

    Shanghai Xunguang XF-EGS8000 Environmental Monitoring Substation

Filter Criteria

Filter Criteria

Instrument Type

Appearance And Installation Type

Measurement Type

Gas Classification

Gas Type

Number Of Channels

#

Response Time

Electrical Output

Show

Operating Temperature

Working Humidity

%

Feature

Application

}