Filter Criteria
Gas Equipment
-
RS Components 1346605
Total of 7 Product Data
Click to View -
TSI Incorporated 854301-1
Total of 1 Product Data
Click to View -
Arjay Engineering EC-Gold Dual
Total of 1 Product Data
Click to View- The electrical output:Current
- According to:Digital
- Working temperature:-4 to 104 F (-20 to 40 C)
- Installation type:Fixed
- Measuring type:%Volume; Trace
- Type of gas:Toxic; CO (0-500ppm); Cl2 (0-10ppm); H2S (0-100ppm); NO2 (0-20ppm); O2 (0-30%)
- The instrument type:Detector; Monitor
- application:Ambient Air Monitoring
- Product category:Gas Instruments
- Number of Gases Monitored:Multi
- Characteristics of the:Audible or Visual Alarms; Controller
-
Acme Engineering Products CO2-EN Series
Total of 1 Product Data
Click to View- The channel number:1
- Characteristics of the:Audible or Visual Alarms; Controller
- The electrical output:Analog Current;Switch
- According to:Digital
- Working temperature:32 to 120 F (0 to 49 C)
- Installation type:Fixed
- Measuring type:Trace
- Type of gas:Toxic; CO2
- The instrument type:Monitor
- application:Confined Space Entry
- Product category:Gas Instruments
- Monitoring gas quantity:Multi
- Sensitivity technology:Infrared
-
LumaSense Technologies INNOVA 1314i
Total of 1 Product Data
Click to View- Response Time:150 seconds
- The channel number:24
- Characteristics of the:Audible or Visual Alarms; Data Logger
- According to:Digital
- Working temperature:41 to 104 F (5 to 40 C)
- Working humidity:80 %
- Installation type:Fixed
- Measuring type:Trace
- Type of gas:Toxic; CO2 (1.5 ppm); Refrigerants (0.01 ppm); NxOx (N2O: 0.03 ppm); SF6 (0.006 ppm) (Halothane, Isoflurane, Methyl Methacrylate (MMA))
- The instrument type:Monitor
- application:Continuous Emissions Monitoring; Ambient Air Monitoring; Process Gas
- Product category:Gas Instruments
- Sensitivity technology:Infrared
- Number of Gases Monitored:Multi
-
Chauvin Arnoux (CA) CA1510
Total of 1 Product Data
Click to View -
MSA TRIGARD®
Total of 5 Product Data
Click to View -
Cubic Sensor and Instrument Co.,Ltd. CTD&CLD Series
Total of 1 Product Data
Click to View- According to:Digital
- Working temperature:14 to 131 F (-10 to 55 C)
- Measuring type:Trace
- Type of gas:Toxic; CO2 (100ppm, 0-500ppm); H2S (0-100ppm)
- The instrument type:Detector
- application:Ambient Air Monitoring
- Sensitivity technology:Electrochemical
- Product category:Gas Instruments
- Number of Gases Monitored:Multi
-
Shenzhen Shenguoan SGA-501/502/503/504/506 series
Total of 16 Product Data
Click to View -
Shanghai Xunguang XF-EGS8000
Total of 1 Product Data
Click to View