Filter Criteria

Product Category

Appearance

Acceleration Range

Frequency Range

Minimum Accuracy

±% Full Scale

Number Of Input Channels

#

Operating Temperature

Maximum Vibration

Maximum Impact

Filter Criteria

  • KXPS5-2050
    • Number of measuring shaft:Single; Biaxial; Triaxial
    • Frequency range:1000 Hz
    • Acceleration range:2 g
    • Working temperature:-40 to 185 F (-40 to 85 C)
    • The biggest impact:5000 g
    • Product form:Linear Accelerometer; Sensor / Transducer
    • Characteristics of the:Environmentally / Hermetically Sealed; Self Test / Self Calibrating
    • Product category:Seismic Instruments
  • 3100D24
    • precision:2.00 ±% Full Scale
    • Number of measuring shaft:Single
    • Frequency range:1 to 1000 Hz
    • Acceleration range:-5 to 5 g
    • The channel number:1
    • Working temperature:-60 to 250 F (-51 to 121 C)
    • The biggest impact:200 g
    • The largest vibration:100 g
    • Appearance of the form:Sensor Only
    • Product form:Linear Accelerometer; Sensor / Transducer
    • Characteristics of the:IEPE; Environmentally / Hermetically Sealed
    • Product category:Seismic Instruments
  • S1SA100S
    • Appearance of the form:Modular
    • Product form:Sensor or Transducer
    • Characteristics of the:IP67
    • Product category:Seismic Instruments
  • VHL3
    • Frequency range:2 to ? Hz
    • Working temperature:-40 to 158 F (-40 to 70 C)
    • Product form:Sensor or Transducer
    • Product category:Seismic Instruments
  • 86
    • Number of measuring shaft:Single
    • Frequency range:0.0050 to 200 Hz
    • Acceleration range:-0.5000 to 0.5000 g
    • Working temperature:-23 to 212 F (-31 to 100 C)
    • The biggest impact:1000 g
    • The largest vibration:10 g
    • Product form:Linear Accelerometer; Sensor / Transducer
    • Characteristics of the:Environmentally / Hermetically Sealed
    • Product category:Seismic Instruments
  • 1521-002
    • Number of measuring shaft:Single
    • Frequency range:0.0 to 400 Hz
    • Acceleration range:-2 to 2 g
    • Working temperature:-67 to 347 F (-55 to 175 C)
    • The biggest impact:6000 g
    • Product form:Linear Accelerometer; Sensor / Transducer
    • Product category:Seismic Instruments
  • 731A&P31
    • Frequency range:0.0500 to 450 Hz
    • Acceleration range:0.5000 g
    • Working temperature:14 to 149 F (-10 to 65 C)
    • The largest vibration:10 g
    • Appearance of the form:Stand Alone
    • Product form:Instrument or Meter or Analyzer
    • Product category:Seismic Instruments
  • 141A/141B linear accelerometer

    Setra 141A/141B linear accelerometer seismic instrument

  • EQ-1211 Single Axis MEMS Capacitive IP65 75g
    • Number of measuring shaft:Single shaft
    • The biggest impact:1500 g
    • Appearance of the form:Modular;
    • Product form:Components/sensor
    • The sensitivity:540-900 mV/g
    • The noise density:0.7-1.2 μg/√Hz
    • Frequency response range:0-700 Hz
    • The amplitude nonlinearity:< 0.3 (typical) | < 1 (maximum)
    • The power supply voltage:5-40 V
    • The temperature coefficient of the scaling factor:120 (typical) | 20 to 220 PPM/K (maximum)
    • Temperature coefficient of deviation:0.3 mm to 1.2 mm (maximum) mg/K
    • Working temperature range:- 40 to + 85 ° C
    • Cable:removable
    • The weight of the:75 g
Filter Criteria

Filter Criteria

Product Category

Appearance

Acceleration Range

Frequency Range

Minimum Accuracy

±% Full Scale

Number Of Input Channels

#

Operating Temperature

Maximum Vibration

Maximum Impact

}