Filter Criteria

Instrument Type

Medium Temperature

Flow Rate

Mass Flow

Liquid Volume Flow

Electrical Output

Work Pressure

Operating Temperature

Interface Options

Pipe Diameter

Installation Type

End Fittings

Feature

Filter Criteria

  • RS Components 1366374

    Total of 2 Product Data

    Click to View
    1366374
    • work pressure:145 psi (102 m H2O)
    • Medium temperature:14 F (-10 C)
    • Pipe diameter:0.50 inch (12.7 mm)
    • The gas volume flow:7.06E-5 to 0.0177 SCFM (1.20E-4 to 0.0300 m³/hr)
    • Product category:Liquid Flow Meters
    • Medium type:Liquid
  • FSS450
    • work pressure:218 to 5802 psi (153 to 4083 m H2O)
    • Medium temperature:-67 to 536 F (-55 to 280 C)
    • Characteristics of the:Programmable
    • The electrical output:Current
    • The interface options:Serial/Digital
    • Working temperature:-40 to 185 F (-40 to 85 C)
    • The terminal fittings:Flanged
    • Pipe diameter:0.50 to 16.00 inch (12.7 to 406 mm)
    • The installation:In-line
    • The instrument type:Mass Flow Meter; Volumetric Flow Meter; Velocity Flow Meter
    • Product category:Liquid Flow Meters
    • Measurement technology:Vortex (Shedding) Meter
    • According to:Digital
    • Additional variable measurement:Temperature
    • Audit certification:ATEX; IECEx, FM, NEPSI, MID/OIML R117
    • precision:0.5000 ±%
    • Panel interface:Digital Front Panel
    • Medium type:Liquid; Gas; Steam
  • PCCLSZZBU
    • The terminal fittings:Threaded
    • The installation:In-line
    • The instrument type:Volumetric Flow Meter
    • According to:Digital
    • Panel interface:Digital Front Panel
    • Product category:Liquid Flow Meters
    • Medium type:Liquid
  • Badger Meter E-25

    Total of 10 Product Data

    Click to View
    E-25
    • work pressure:175 psi (123 m H2O)
    • The liquid volume flow:0.10 to 25.00 GPM (0.3788 to 94.7 L/min)
    • Medium temperature:34 to 140 F (1 to 60 C)
    • Working temperature:-40 to 140 F (-40 to 60 C)
    • The terminal fittings:Threaded
    • Pipe diameter:0.62 to 0.75 inch (15.87 to 19.05 mm)
    • The installation:In-line
    • The instrument type:Volumetric Flow Meter
    • Product category:Liquid Flow Meters
    • Measurement technology:Ultrasonic
    • Medium type:Liquid
  • OPTISONIC 6300 P
    • Medium temperature:-40 to 248 F (-40 to 120 C)
    • Characteristics of the:Programmable;Controller
    • The electrical output:Current; Frequency
    • The interface options:Network/Fieldbus; Pulse
    • Working temperature:-40 to 158 F (-40 to 70 C)
    • The terminal fittings:Clamp
    • Pipe diameter:0.50 to 60.00 inch (12.7 to 1524 mm)
    • The installation:In-line
    • The instrument type:Mass Flow Meter; Volumetric Flow Meter; Velocity Flow Meter
    • Product category:Liquid Flow Meters
    • Audit certification:CE, EN, EC, IEC, NEMA
    • Medium type:Liquid
    • According to:Digital
    • Panel interface:Digital Front Panel
    • Measurement technology:Ultrasonic
    • precision:3 ±%
  • Portable Liquid Flow Meters - InnovaSonic® 210
    • The velocity:0.3000 to 40 ft/sec (0.0914 to 12.19 m/sec)
    • Medium temperature:-40 to 176 F (-40 to 80 C)
    • Characteristics of the:Recorder / Totalizer Functions; Suspended Solids / Slurries
    • The electrical output:Current
    • Working temperature:14 to 122 F (-10 to 50 C)
    • The terminal fittings:Clamp
    • Pipe diameter:2.00 to 236.00 inch (50.8 to 5994 mm)
    • The installation:Non-Invasive
    • The instrument type:Velocity Flow Meter
    • precision:0.5000 ±%
    • Medium type:Liquid
    • According to:Digital
    • Panel interface:Digital Front Panel
    • Product standards:RoHS; WEEE Compliant
    • Audit certification:CE, ISO 9001
    • Product category:Liquid Flow Meters
    • Measurement technology:Ultrasonic
  • Plast-O-Matic FSA100

    Total of 6 Product Data

    Click to View
    FSA100
    • The electrical output:Switch
    • The terminal fittings:Threaded
    • Pipe diameter:1.00 inch (25.4 mm)
    • The installation:In-line
    • The instrument type:Volumetric Flow Meter
    • Product category:Liquid Flow Meters
    • Medium type:Liquid
  • FS10A
    • work pressure:0.0 to 600 psi (0.0 to 422 m H2O)
    • The liquid volume flow:0.00 to 0.03 GPM (0.0038 to 0.1136 L/min)
    • Medium temperature:-40 to 500 F (-40 to 260 C)
    • Characteristics of the:Built-in Alarm Indicator
    • The electrical output:Current (optional feature); Switch
    • Working temperature:-40 to 160 F (-40 to 71 C)
    • The terminal fittings:Flanged; In-line Threaded
    • Pipe diameter:0.25 to 0.50 inch (6.35 to 12.7 mm)
    • The installation:Insertion
    • The instrument type:Volumetric Flow Meter
    • precision:0.5000 ±%
    • Additional variable measurement:Temperature
    • Audit certification:ATEX; FM, FMc, IECEx, CE Mark, CRN, ANSI / ISA 12.27.01-2011, SIL
    • Direct current voltage:24 volts
    • The gas volume flow:0.1000 to 20 SCFM (0.1700 to 33.99 m³/hr)
    • Measurement technology:Thermal
    • Switch to normal:Normally Open
    • Medium type:Liquid; Gas
    • Product category:Liquid Flow Meters
    • Switch type:Solid State
  • ES-FLOW ES-103I
    • work pressure:0.0 to 928 psi (0.0 to 653 m H2O)
    • The liquid volume flow:0.00 to 0.40 GPM (0.0040 to 1.5 L/min)
    • Medium temperature:50 to 185 F (10 to 85 C)
    • Characteristics of the:Built-in Alarm Indicator;Controller;Recorder / Totalizer Functions; Sanitary Applications Rated
    • The electrical output:Current; Frequency; Voltage
    • The interface options:Serial/Digital; Network/Fieldbus
    • Working temperature:50 to 140 F (10 to 60 C)
    • The terminal fittings:Flanged
    • Pipe diameter:0.00 to 0.50 inch (0.0 to 12.7 mm)
    • The installation:In-line
    • The instrument type:Volumetric Flow Meter
    • Product category:Liquid Flow Meters
    • Medium type:Liquid
    • According to:Digital
    • Panel interface:Digital Front Panel; Computer Controllable
    • Product standards:RoHS
    • Measurement technology:Ultrasonic
  • Transi-Flo II
    • work pressure:0.0 to 217 psi (0.0 to 153 m H2O)
    • The liquid volume flow:0.55 to 13758.00 GPM (2.08 to 52114 L/min)
    • Medium temperature:32 to 302 F (0 to 150 C)
    • Characteristics of the:Programmable; Recorder / Totalizer Functions;Controller
    • The electrical output:Current ; Frequency; Voltage
    • The interface options:Serial/Digital
    • The terminal fittings:Flanged
    • Pipe diameter:1.25 to 12.00 inch (31.75 to 305 mm)
    • The installation:In-line
    • The instrument type:Volumetric Flow Meter
    • Panel interface:Digital Front Panel (optional feature); Computer Controllable (optional feature)
    • Product category:Liquid Flow Meters
    • Audit certification:ISO 9001
    • Measurement technology:Ultrasonic
    • Medium type:Liquid
Filter Criteria

Filter Criteria

Instrument Type

Medium Temperature

Flow Rate

Mass Flow

Liquid Volume Flow

Electrical Output

Work Pressure

Operating Temperature

Interface Options

Pipe Diameter

Installation Type

End Fittings

Feature

}