Filter Criteria

Instrument Type

Medium Temperature

Flow Rate

Mass Flow

Liquid Volume Flow

Electrical Output

Work Pressure

Operating Temperature

Interface Options

Pipe Diameter

Installation Type

End Fittings

Feature

Filter Criteria

  • CoriolisMaster - FCB130 & 150
    • Medium temperature:-58 to 400 F (-50 to 204 C)
    • Characteristics of the:Programmable
    • The electrical output:Current
    • The terminal fittings:Flanged ; Threaded
    • The installation:In-line
    • The instrument type:Mass Flow Meter; Volumetric Flow Meter
    • Medium type:Liquid
    • Audit certification:MID/OIML R117 certified
    • Product category:Liquid Flow Meters
    • Measurement technology:Coriolis
  • PCCLSZZBU
    • The terminal fittings:Threaded
    • The installation:In-line
    • The instrument type:Volumetric Flow Meter
    • According to:Digital
    • Panel interface:Digital Front Panel
    • Product category:Liquid Flow Meters
    • Medium type:Liquid
  • Badger Meter 340 BN&MB

    Total of 14 Product Data

    Click to View
    340 BN&MB
    • Characteristics of the:Programmable
    • The electrical output:Frequency
    • Working temperature:-20 to 158 F (-29 to 70 C)
    • Medium type:Liquid
    • Panel interface:Computer Controllable
    • Additional variable measurement:Temperature
    • Product category:Liquid Flow Meters
  • Plast-O-Matic FSA100

    Total of 6 Product Data

    Click to View
    FSA100
    • The electrical output:Switch
    • The terminal fittings:Threaded
    • Pipe diameter:1.00 inch (25.4 mm)
    • The installation:In-line
    • The instrument type:Volumetric Flow Meter
    • Product category:Liquid Flow Meters
    • Medium type:Liquid
  • ES-FLOW ES-103I
    • work pressure:0.0 to 928 psi (0.0 to 653 m H2O)
    • The liquid volume flow:0.00 to 0.40 GPM (0.0040 to 1.5 L/min)
    • Medium temperature:50 to 185 F (10 to 85 C)
    • Characteristics of the:Built-in Alarm Indicator;Controller;Recorder / Totalizer Functions; Sanitary Applications Rated
    • The electrical output:Current; Frequency; Voltage
    • The interface options:Serial/Digital; Network/Fieldbus
    • Working temperature:50 to 140 F (10 to 60 C)
    • The terminal fittings:Flanged
    • Pipe diameter:0.00 to 0.50 inch (0.0 to 12.7 mm)
    • The installation:In-line
    • The instrument type:Volumetric Flow Meter
    • Product category:Liquid Flow Meters
    • Medium type:Liquid
    • According to:Digital
    • Panel interface:Digital Front Panel; Computer Controllable
    • Product standards:RoHS
    • Measurement technology:Ultrasonic
  • Transi-Flo II
    • work pressure:0.0 to 217 psi (0.0 to 153 m H2O)
    • The liquid volume flow:0.55 to 13758.00 GPM (2.08 to 52114 L/min)
    • Medium temperature:32 to 302 F (0 to 150 C)
    • Characteristics of the:Programmable; Recorder / Totalizer Functions;Controller
    • The electrical output:Current ; Frequency; Voltage
    • The interface options:Serial/Digital
    • The terminal fittings:Flanged
    • Pipe diameter:1.25 to 12.00 inch (31.75 to 305 mm)
    • The installation:In-line
    • The instrument type:Volumetric Flow Meter
    • Panel interface:Digital Front Panel (optional feature); Computer Controllable (optional feature)
    • Product category:Liquid Flow Meters
    • Audit certification:ISO 9001
    • Measurement technology:Ultrasonic
    • Medium type:Liquid
  • TM Series
    • work pressure:225 psi (158 m H2O)
    • The liquid volume flow:1.00 to 600.00 GPM (3.79 to 2273 L/min)
    • Characteristics of the:Programmable; Recorder / Totalizer Functions
    • The electrical output:Current; Frequency
    • Working temperature:32 to 140 F (0 to 60 C)
    • The terminal fittings:Flanged; In-line Threaded; Spigot
    • Pipe diameter:0.50 to 4.00 inch (12.7 to 102 mm)
    • The installation:In-line
    • The instrument type:Volumetric Flow Meter
    • Measurement technology:Turbine
    • According to:Digital
    • Medium type:Liquid
    • Product category:Liquid Flow Meters
    • precision:3 ±%
  • 26600
    • work pressure:400 psi (282 m H2O)
    • Working temperature:-20 to 180 F (-29 to 82 C)
    • The gas volume flow:0.1003 to 0.5348 SCFM (0.1704 to 0.9090 m³/hr)
    • Product category:Liquid Flow Meters
    • Medium type:Liquid
    • manufacturers:Gems Sensors & Controls
    • Product model:26600
  • ifm SB1233

    Total of 15 Product Data

    Click to View
    SB1233
    • work pressure:1450 psi (1021 m H2O)
    • The liquid volume flow:0.13 to 6.61 GPM (0.4924 to 25.03 L/min)
    • Medium temperature:14 to 212 F (-10 to 100 C)
    • Working temperature:32 to 140 F (0 to 60 C)
    • Audit certification:ce, cul, iolink
    • Product category:Liquid Flow Meters
    • Medium type:Liquid
    • The gas volume flow:0.0174 to 0.8828 SCFM (0.0295 to 1.5 m³/hr)
    • Product standards:RoHS
Filter Criteria

Filter Criteria

Instrument Type

Medium Temperature

Flow Rate

Mass Flow

Liquid Volume Flow

Electrical Output

Work Pressure

Operating Temperature

Interface Options

Pipe Diameter

Installation Type

End Fittings

Feature

}